4.4 Maintenance, Diagnostic Commands

a.Page code list

This parameter page specifies transfer of the "Page code" list of the parameter page supported by the HDD in the SEND DIAGNOSTIC command and the RECEIVE DIAGNOSTIC RESULTS command to the INIT. Table 4.51 shows the format of this parameter page. The page code list supported by the HDD is transferred to the INIT by the RECEIVE DIAGNOSTIC RESULTS command which is issued following the SEND DIAGNOSTIC command that specifies this parameter page (shown in Section 4.4.2 (1) )

Table 4.51 SEND DIAGNOSTIC parameters: page code list

 

Bit

7

6

5

 

4

3

2

1

0

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

X '00' (Page Code)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

0

0

0

 

0

0

0

0

0

 

 

 

 

 

 

 

 

2

 

 

 

X '00'

(Page parameter length)

 

 

 

 

 

 

 

 

 

 

3

 

 

 

X '00'

(Page parameter length)

 

 

 

 

 

 

 

 

 

 

 

 

 

b.PHY Test function

This parameter instructs the execution of the PHY Test function for the specified PHY. The SEND DIAGNOSTIC command is used to send page data to INIT. When the RECEIVE DIAGNOSTICS RESULTS command is executed with "0x3F" specified for the page code file, the HDD ends with a failure with CHECK CONDITION status (ILLEGAL REQUEST [=5] / Invalid field in parameter list [=26-00]).

Table 4.52 shows the configuration of this parameter page.

C141-C013

251

Page 255
Image 255
Fujitsu MBC2036RC, MBC2073RC, MBA3300RC, MBA3147RC, MBA3073RC specifications Send Diagnostic parameters page code list