4.1 Control/Sense Commands

a.Page code

This field identifies which log page is being transferred.

The log pages that can be transferred by this command are shown in Table 4.21.

Table 4.21 Page code

Page Code

Description

Changeable Parameter

 

 

 

01

Buffer Overrun/Underrun Page

Disable

02

Write Error Counter Page

Enable

03

Read Error Counter Page

Enable

05

Verify Error Counter Page

Enable

06

Non-medium Error Page

Enable

0D

Temperature Page

Disable

0E

Start-stop Cycle Counter Page

Enable only 0002

0F

Application Client Log Page

Enable

10

Self-Test Result Log Page

Disable

15

Background Medium Scan Page

Disable

18

Protocol Specific Port Log Page

Disable

 

 

 

b. Page length

This field specifies the length in bytes of the following log parameters. If the application client sends a page length that results in the truncation of any parameter, the device server terminates the command with CHECK CONDITION status (ILLEGAL REQUEST [=5] / Invalid field in parameter list [=26-00]).

The log pages contain one or more special data structures called log parameters as shown below. Each log parameter begins with a 4-byte parameter header followed by one or more bytes of "Parameter Value" data.