Fujitsu MBA3073RC, MBC2036RC, MBC2073RC, MBA3300RC, MBA3147RC Accounting date page 0E, code

Models: MBA3300RC MBA3147RC MBA3073RC MBC2073RC MBC2036RC

1 439
Download 439 pages 37.87 Kb
Page 349
Image 349

5.2 Log Parameters

Accounting date (page 0E, code 0002)

Table 5.51 Accounting date (page 0E, code 0002)

Byte

Bit

7

6

5

4

 

3

 

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

(MSB)

 

X'0002' (Parameter code)

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

(Accounting Date)

 

 

 

 

(LSB)

 

 

 

 

 

 

 

 

 

 

 

6

 

DU

DS

TSD

ETC

 

 

TMC

LBIN

LP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

0

0

 

0

0

0

1

 

 

 

 

 

 

 

 

 

 

7

 

 

 

X'06' (Parameter Length)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

(MSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

Accounting date Year (4 ASCII characters)

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

(LSB)

 

 

 

 

 

 

 

 

 

 

 

 

12

 

(MSB)

Accounting date week (2 ASCII characters)

 

 

 

 

 

13

 

 

(LSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The Accounting date specified by parameter code 0002h is a parameter that may be savable using a LOG SELECT command to indicate when the device was placed in service. If the parameter is not yet set or is not settable, the default value placed in the parameter field shall be 6 ASCII blank characters (20h). The field shall not be checked for validity by the device server.

Specified cycle count over device lifetime (page 0E, code 0003)

Table 5.52 Specified cycle count over device lifetime (page 0E, code 0003)

Byte

Bit

7

6

5

4

 

3

 

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

(MSB)

X'0003' (Parameter code)

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

(Specified Cycle Count Over Device Lifetime)

(LSB)

 

 

 

 

 

 

 

 

 

 

 

6

 

DU

DS

TSD

ETC

 

 

TMC

LBIN

LP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

0

0

 

0

0

1

1

 

 

 

 

 

 

 

 

 

 

7

 

 

 

X'04' (Parameter Length)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

(MSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

Specified Cycle Count Over Device Lifetime

 

10

 

 

 

(4-byte binary number)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

(LSB)

 

 

 

 

 

 

 

 

 

 

 

 

C141-C013

345

Page 349
Image 349
Fujitsu MBA3073RC, MBC2036RC Accounting date page 0E, code, Specified cycle count over device lifetime page 0E, code