5.2 Log Parameters

 

When the self-test is initiated, the value specified in the SELF-TEST CODE field

 

in the CDB is reported to the SELF-TEST CODE field by a SEND

 

DIAGNOSTICS command.

 

The values reported to the "Self-Test Result Value" field are defined in Table 5.58.

 

Table 5.58 Self-test results values

 

 

Value

Description

 

 

 

 

0h

The self-test completed without error.

 

1h

The background self-test was aborted by the application client using a SEND

 

 

DIAGNOSTICS command with the SELF-TEST CODE field set to 100b

 

 

(Abort background self-test).

 

2h

The self-test routine was aborted by an application client using a method other

 

 

than a SEND DIAGNOSTICS command with the SELF-TEST CODE field set

 

 

to 100b (e.g., reception of the ABORT Task, RESET CONDITION.

 

3h

An unknown error occurred while the device server was executing the self-test

 

 

and the device server was unable to complete the self-test.

 

4h

The self-test completed with a failure in a test segment, and the test segment

 

 

that failed is not known.

 

5h

The first segment of the self-test failed.

 

6h

The second segment of the self-test failed.

 

7h

Another segment of the self-test failed (see the SELF-TEST SEGMENT

 

 

NUMBER field).

 

8h – Eh

Reserved

 

Fh

The self-test is in progress.

 

 

 

 

The number of the segment that failed during the self-test is shown in the "Self- Test Segment Number" field. When the self-test is completed without an error, 0 is shown in the field.

The accumulated power-on time (unit: hour) in the event of an error occurring in the drive is shown in the "Time Stamp" field.

Address information of the data block where that error occurred is shown in the "Address of First Failure" field.

The error information in the same format as that used by sense data is reported to the "Sense Key," "Additional Sense Code," and "Additional Sense Code Qualifier" fields.

C141-C013

349

Page 353
Image 353
Fujitsu MBA3147RC, MBC2036RC, MBC2073RC, MBA3300RC, MBA3073RC specifications Self-test results values