Fujitsu MBA3300RC Notch Parameters Page Code = 0C, Mode Select parameters notch parameters

Models: MBA3300RC MBA3147RC MBA3073RC MBC2073RC MBC2036RC

1 439
Download 439 pages 37.87 Kb
Page 312
Image 312

Parameter Data Format

5.1.8 Notch Parameters (Page Code = 0C)

Table 5.10 MODE SELECT parameters: notch parameters

 

Bit

7

6

5

 

4

 

3

 

2

1

0

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

0

0

0

0

1

 

1

0

0

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

X'16' (Page Length)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

ND

LPN

 

 

 

 

X'00' (Reserved)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

0

0

0

0

0

 

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

Variable

0

1

0

0

0

 

0

0

0

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

X'00' (Reserved)

 

 

 

 

 

 

 

 

 

 

 

4-5

 

 

 

Maximum number of notches

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

 

 

 

 

 

X'001D'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable

 

 

 

 

 

X'0000'

 

 

 

 

 

 

 

 

 

 

 

 

 

6-7

 

 

 

 

Active Notch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

 

 

 

 

 

X'0000'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable

 

 

 

 

 

X'FFFF'

 

 

 

 

 

 

 

 

 

 

 

 

 

8-11

 

 

 

 

Starting Boundary

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

 

 

 

 

X'00000000'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable

 

 

 

 

X'00000000'

 

 

 

 

 

 

 

 

 

 

 

 

 

12-15

 

 

 

 

Ending Boundary

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

 

 

 

 

X'xxxxxxxx'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable

 

 

 

 

X'00000000'

 

 

 

 

 

 

 

 

 

 

 

 

 

16-23

 

 

 

 

Page Notch

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

 

 

 

X'0000000000000008'

 

 

 

 

 

 

 

 

 

 

 

 

 

Variable

 

 

 

X'0000000000000000'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This page is used to report the top address and final address of each zone.

If the zone number + 1 of the notching zone is set in the "Active notch" field and this parameter is issued, the starting and ending address of the specified zone can be referred to by the MODE SENSE command.

Also, if Page 3 and Page 3F are specified by the MODE SENSE command, the parameters below the zone specified in the notch page can be referred to.

Track/zone (Page 3, Byte 02, 03) (Note)

Sector count/track (Page 3, Bytes 10, 11)

Track Skew Factor (Page 3, Bytes 16, 17)

Cylinder Skew Factor (Page 3, Bytes 18, 19)