Fujitsu MBA3073RC, MBC2036RC, MBC2073RC, MBA3300RC, MBA3147RC specifications Request Sense

Models: MBA3300RC MBA3147RC MBA3073RC MBC2073RC MBC2036RC

1 439
Download 439 pages 37.87 Kb
Page 189
Image 189

4.1 Control/Sense Commands

4.1.14 REQUEST SENSE (03)

Byte

Bit

7

6

5

 

4

 

3

 

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

X'03'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

0

0

0

 

0

0

 

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

2

 

0

0

0

0

0

 

0

0

0

 

 

 

 

 

 

 

 

 

 

 

3

 

0

0

0

0

0

 

0

0

0

 

 

 

 

 

 

 

 

 

4

 

 

 

 

Transfer Byte Length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

0

0

0

0

0

 

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

This command transfers sense data to the INIT.

This command is executed in any state other than a CDB specification error.

The sense data of the HDD has a length of 48 bytes. The HDD generates sense data in any of the following cases and holds the sense data for the INIT that has issued the relevant command:

If this command is executed when the HDD is holding the Unit Attention condition, at that point, if the HDD is not in the sense data hold state, sense data showing the Unit Attention condition are created by this command and are sent to the INIT, and the Unit Attention condition is cleared.

If this command is issued when no valid sense data are being held, the HDD sends sense data with a sense key which shows "NO SENSE".

The "Transfer Byte Length" field in the CDB show the number of bytes of sense data that can be received by the INIT. The HDD transfers sense data with a length that is specified in the "Transfer Byte Length" field or the HDD's own sense data length (48 bytes), whichever is smaller.

When the value specified in the "Transfer Byte Length" shows 48 bytes or more, 48 bytes of sense data are transferred and the command terminates with the "GOOD" status.

This command reports the "CHECK CONDITION" status and terminates abnormally only in the cases where the conditions shown below are detected. In this case, new sense data are generated and the sense data held up to that time are lost.

C141-C013

185

Page 189
Image 189
Fujitsu MBA3073RC, MBC2036RC, MBC2073RC, MBA3300RC, MBA3147RC specifications Request Sense