7.4 Background Media Scan (BMS)

Table 7.3 BMS Status parameter format

 

 

 

 

 

Bit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

6

5

 

4

 

3

 

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

Byte 0

(MSB)

 

 

Parameter Code (0x0000)

 

 

 

 

 

 

 

 

1

 

 

 

 

(LSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

DU

DS

TSD

 

ETC

 

 

TMC

LBIN

LP

 

 

 

 

 

 

 

 

 

 

 

 

0

0

0

 

0

 

0

0

1

1

 

 

 

 

 

 

 

 

 

3

 

 

 

Parameter Length (0x0C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

(MSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

Time Stamp

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

(LSB)

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

BMS Status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

(MSB)

 

 

Number of Scan Performed

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

(MSB)

 

 

 

Medium Scan Progress

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

(LSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The "Time Stamp" field contains the cumulative power-on time in minutes, which will be reported when the LOG SENSE command is issued. The values that may be reported in the "BMS Status" field are as follows:

"0h"

Scanning is not in process.

 

 

"1h"

Background Medium Scan processing is in progress.

 

 

"2h"

Pre-Scan processing is in progress.

 

 

"3h"

Scanning stopped due to a hardware error or because the SMART test

 

phase was reached.

 

 

"4h"

Reserved

 

 

"5h"

Scanning stopped because a format without a P-List was encountered.

 

 

"6h"

Reserved

 

 

"7h"

Scanning stopped because the temperature dropped below 10°C or

 

exceeded 60°C.

 

 

"8h"

During an interval.

 

 

C141-C013

401

Page 405
Image 405
Fujitsu MBC2036RC, MBC2073RC, MBA3300RC, MBA3147RC, MBA3073RC specifications BMS Status parameter format