Fujitsu MBA3147RC, MBC2036RC Transport layer, Frame Type field, Nodata, Responsedata, Sensedata

Models: MBA3300RC MBA3147RC MBA3073RC MBC2073RC MBC2036RC

1 439
Download 439 pages 37.87 Kb
Page 83
Image 83

1.6 Transport layer

Table 1.33 defines the FRAME TYPE field.

Table 1.33 FRAME TYPE field

Code

Name of frame

Information Unit

Originator

Information unit size

(bytes)

 

 

 

 

 

 

 

 

 

01h

DATA frame

DATA

INIT or TARG

1 to 1024

 

 

 

 

 

05h

XFER_RDY

Transfer ready

SSP TARG port

12

 

frame

 

 

 

 

 

 

 

 

06h

COMMAND

Command

SSP INIT port

28 to 280

 

frame

 

 

 

 

 

 

 

 

07h

RESPONSE frame

Response

SSP TARG port

NO_DATA: 24

 

 

 

 

 

 

 

 

 

RESPONSE_DATA: 28

 

 

 

 

 

 

 

 

 

SENSE_DATA: 72

 

 

 

 

 

16h

TASK frame

Task

SSP INIT port

28

 

 

management

 

 

 

 

function

 

 

 

 

 

 

 

All others

Reserved (unknown frame)

 

 

 

 

 

 

 

The HASHED DESTINATION SAS ADDRESS field contains the hashed value of the destination SAS address.

The HASHED SOURCE SAS ADDRESS field contains the hashed value of the source SAS address

The RETRY DATA FRAMES bit is set to one for XFER_RDY frames and shall be set to zero for all other frame types. When set to one this bit specifies that the SSP INIT port may retry write DATA frames that fail.

The RETRANSMIT bit is set to one for TASK frames, RESPONSE frames, and XFER_RDY frames and shall be set to zero for all other frame types. This bit specifies that the frame is a retransmission after the SSP port failed in its previous attempt to transmit the frame.

The CHANGING DATA POINTER bit is set to one for DATA frames and shall be set to zero for all other frame types. When set to one this bit specifies that the frame is a retransmission after the SSP TARG port failed in its previous attempt to transmit the frame or a subsequent frame and the dataoffset field of the frame may not be sequentially increased from that of the previous frame.

The NUMBER OF FILL BYTES field specifies the number of fill bytes between the INFORMATION UNIT field and the CRC field. The NUMBER OF FILL BYTES field shall be set to zero for all frame types except DATA frames (i.e., all other frame types are already four-byte aligned).