4.4 Maintenance, Diagnostic Commands

PHY Identifier

Specify the PHY that will become the operation target of the PHY Test function.

If a value other than either of the values below is specified, HDD processing ends with a failure with CHECK CONDITION status "ILLEGAL REQUEST [=5]/ Invalid field in parameter list [=26-00]".

0h: Primary Port (Port-A)

1h: Secondary Port (Port-B)

PHY Test Function

Specify the operation to be performed by the PHY Test function.

If a value other than any of the values below is specified, HDD processing ends with a failure with CHECK CONDITION status "ILLEGAL REQUEST [=5]/ Invalid field in parameter list [=26-00]".

00h: Stops PHY Test function

If the PHY Test function is already stopped, the PHY Test function returns "Good Status."

01h: Starts PHY Test function

If the PHY Test function is already started, HDD processing ends with a failure with CHECK CONDITION status "ILLEGAL REQUEST [=5]/ PHY Test in progress [=47-06]".

PHY Test Pattern

Specify the PHY Test Pattern sent from INIT.

If a value other than any of the values below is specified, HDD processing ends with a failure with CHECK CONDITION status "ILLEGAL REQUEST [=5]/ Invalid field in parameter list [=26-00]".

01h: JTPAT

02h: CJTPAT

40h: TWODWORDS

The DWORD specified in the PHY Test Pattern DWORDS field is repeated and sent.

C141-C013

253

Page 257
Image 257
Fujitsu MBA3300RC, MBC2036RC, MBC2073RC, MBA3147RC, MBA3073RC specifications Maintenance, Diagnostic Commands