Parameter Data Format

The HDD does not support this bit. It always reports "0" in response to the LOG SENSE command (see Section 4.1.15). The LOG SELECT command will be accepted when this bit value is "1." However, the HDD will save the target with a specific algorithm, ignoring the value specified in the command.

e.ETC (Enable Threshold Comparison)

The HDD does not support this bit. It always reports "0" to the LOG SENSE command (see Section 4.1.15). The HDD will accept this command when this bit is "1." However, the HDD will not compare the log parameter with the threshold, ignoring the value specified in the command.

f.TMC (Threshold Met Criteria)

This field is invalid because the "ETC" bit is "0." The LOG SELEVT command (see Section 4.1.15) will be accepted when the value of this field is not "00b." However, the HDD will ignore the value specified in the command. Note that "0" will be posted for the LOG SENSE command.

g.LBIN

This bit is only valid when the "LP" bit is "1." When the "LP" bit is "1" and this bit is "0," the list parameter is represented by ASCII codes. When the LP" bit is "1" and this bit is "1," the list parameter is represented by binary codes.

h.LP (List Parameter)

"1": The parameter is a data counter.

"0": The parameter is a list parameter.

If this bit is specified by the LOG SELECT command, the HDD ignores the specified value and its operation is not affected.

328

C141-C013

Page 332
Image 332
Fujitsu MBA3300RC, MBC2036RC, MBC2073RC, MBA3147RC, MBA3073RC specifications Parameter Data Format