Fujitsu MBC2036RC, MBC2073RC Breaking a connection, Break connection responses, Rate matching

Models: MBA3300RC MBA3147RC MBA3073RC MBC2073RC MBC2036RC

1 439
Download 439 pages 37.87 Kb
Page 75
Image 75

1.5 Address frames

1.5.5.7Breaking a connection

In addition to aborting a connection request, BREAK may also be used to break a connection, in cases where CLOSE is not available. After transmitting BREAK, the originating phy shall ignore all incoming dwords except for BREAKs.

After transmitting BREAK, the source phy shall initialize a Break Timeout timer to 1 ms and start the Break Timeout timer. Table 1.29 lists the responses to a BREAK being transmitted after a connection has been established.

 

Table 1.29 Break connection responses

 

 

 

Response

 

Description

 

 

 

BREAK

 

This confirms that the connection has been broken.

 

 

 

Break Timeout

 

The originating phy shall assume the connection has been

timer expires

 

broken. The originating phy may perform a link reset

 

 

sequence.

 

 

 

In addition to a BREAK, a connection is considered broken due to loss of dword synchronization.

The following shall be the responses by an SSP phy to a broken connection:

a)Received frames having no CRC error may be considered valid regardless of whether an ACK has been transmitted in response to the frame prior to the broken connection;

b)Transmitted frames for which an ACK has been received prior to a broken connection shall be considered successfully transmitted; and

c)Transmitted frames for which an ACK or NAK has not been received prior to a broken connection shall be considered not successfully transmitted.

1.5.5.8Rate matching

In spite of the fact that the physical link is set to 3.0 Gbps, the connection rate (indicated in an OPEN address frame) may be 1.5 Gbps. As shown in Table 1.30, if the transfer rate of the physical link is higher than the connection rate, ALIGN or NOTIFY primitives must be inserted between dwords for each phy of the pathway.

C141-C013

71

Page 75
Image 75
Fujitsu MBC2036RC, MBC2073RC, MBA3300RC, MBA3147RC Breaking a connection, Break connection responses, Rate matching