4.1 Control/Sense Commands

 

 

Table 4.15 Mode page

 

 

 

 

 

 

 

 

Page Code

Page Descriptor Name SCSI-3

Byte

 

 

 

 

 

 

 

1

Read/Write Error Recovery Parameter

12 bytes

 

 

2

Disconnect/Reconnect Parameter

16 bytes

 

 

3

Format Parameter

24 bytes

 

 

4

Drive Parameter

24 bytes

 

 

7

Verify Error Recovery Parameter

12 bytes

 

 

8

Read Caching Parameter

20 bytes

 

 

A

Control Mode Parameter

12 bytes

 

 

C

Notch Parameter

24 bytes

 

 

19

Port Control Parameter

8 bytes

 

 

 

(Sub Page 00)

 

 

 

(Sub Page 01)

104 bytes

 

 

1A

Power Condition Parameter

12 bytes

 

 

1C

Information Exception Control Parameter

12 bytes

 

 

 

(Sub Page 00)

 

 

 

(Sub Page 01)

16 bytes

 

 

21

Additional Error Recovery Parameter

4 bytes

 

 

3F

All Page Descriptors Supported by the HDD

180 bytes

 

 

 

(Sub Page 00)

 

 

 

(Sub Page FF)

300 bytes

 

When the value specified in the "Page code" field is other than X '3F', the specified "Page descriptor" only is transferred to the INIT, and when X '3F' is specified, all the "Page descriptors" supported by the HDD are transferred to the INIT in the ascending order of the page code. Also, when X '00' is specified in the "Page code field," the "Page descriptor" is not transferred. If page codes other than the above mentioned ones ("Page descriptors" which are not supported by the HDD) are specified, the command is terminated with a CHECK CONDITION status (ILLEGAL REQUEST [=5] / Invalid field in CDB [=24-00]).

Also the "PC (page control)" field in CDB byte 2 specifies the type of parameter value in the "Page descriptor" transferred to the INIT by this command, as shown in Table 4.16.

Even in cases where the value specified in the MODE SELECT or MODE SELECT EXTENDED command is described in Table 4.16 as the value reported to the INIT by this command, if parameter rounding processing is applied by the HDD, or in cases of a parameter or bit with a specified value that is disregarded, different values than those specified by the INIT will be reported. For details, see the descriptions of each page descriptor (in Chapter 5). Also, "0" is reported in byte positions and bit positions which are reserved in each page descriptor.