Parameter Data Format

Total unrecoverable read errors posted to INIT (page 03, code 0006)

Table 5.37 Total unrecoverable read errors posted to INIT (page 03, code 0006)

Byte

Bit

7

6

5

4

3

 

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

(MSB)

 

X'0006' (Parameter code)

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

(Total Posted Unrecoverable Errors)

(LSB)

 

 

 

 

 

 

 

 

 

 

6

 

DU

DS

TSD

ETC

 

TMC

LBIN

LP

 

 

 

 

 

 

 

 

 

 

 

 

0

0

0

0

0

0

0

0

 

 

 

 

 

 

 

 

 

7

 

 

 

X'04' (Parameter Length)

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

(MSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

Counter Value

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

(LSB)

 

 

 

 

 

 

 

 

 

 

 

The Counter Value indicates the count of all posted unrecovered errors (03/xx/xx) to the interface during read operations. The value includes the count of all posted unrecovered verify errors (page X'05', Parameter code X'0006').

5.2.5 Verify Error Count Page (X'05')

Table 5.38 Verify error count page (X'05')

Byte

Bit

7

6

5

 

4

3

 

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

0

0

0

0

 

1

0

1

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

X'00' (Reserved)

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

Page Length (MSB)

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

Page Length (LSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All of the following parameters have this header.

Page Length will be defined based on the value of Parameter Pointer. (CDB 5-6)

338

C141-C013

Page 342
Image 342
Fujitsu MBA3300RC, MBC2036RC, MBC2073RC, MBA3147RC, MBA3073RC specifications Verify Error Count, Verify error count