7.6SMART (Self-Monitoring Analysis and Reporting Technology)

h.DE temperature

The HDD measures the device temperature at one-minute intervals. It also measures the temperature under one of the following conditions:

When the LOG SENSE command is executed (Log Page 0D or 2F)

When the REQUEST SENSE command is executed

When retry processing is performed

If the EWASC bit (MODE SELECT parameter on Page 1C) is set and the measured temperature exceeds the threshold specified by the log parameter (Page 0D), the HDD issues a warning (Specified temperature exceeded [=0B- 01]).

Table 7.6 SMART thresholds

 

Attribute

Threshold (sample size)

 

 

 

a

Read error rate

300 errors (1,000,000 read sectors)

 

 

 

b

Write error rate

300 errors (1,000,000 written

 

 

sectors)

 

 

 

c

Seek error rate

300 errors (1,000,000 seeks)

 

 

 

d

Number of remaining alternate

200 spare sectors

 

sectors

 

 

 

 

e

Spin-up time

55 seconds (2 consecutive times)

 

 

 

f

G-list update frequency attribute

300 times (1,000,000 read sectors)

 

 

 

g

Cumulative power-on time

45,000 hours (no failure prediction

 

 

report)

 

 

 

h

DE temperature

65oC

 

 

 

C141-C013

415

Page 419
Image 419
Fujitsu MBA3073RC, MBC2036RC, MBC2073RC, MBA3300RC, MBA3147RC specifications Smart thresholds