Fujitsu MBA3073RC, MBC2036RC, MBC2073RC, MBA3300RC, MBA3147RC specifications Enable Spinup

Models: MBA3300RC MBA3147RC MBA3073RC MBC2073RC MBC2036RC

1 439
Download 439 pages 37.87 Kb
Page 369
Image 369

6.1 Sense Data

Table 6.4 Additional Sense Code and Additional Sense Code Qualifier (1/6)

C*

Q*

Name

Explanation

Sense

key

 

 

 

 

 

 

 

 

 

00

00

No additional sense

No specific sense code exists.

0

 

 

information

 

 

 

 

 

 

 

01

00

No index/sector signal

The target sector was not detected by the sector counter within

4

 

 

 

the specified time.

 

 

 

 

 

 

03

00

Peripheral device write fault

A write operation to the disk media was terminated abnormally.

1, 3, B

 

 

 

∙ Off track during write.

 

 

 

 

 

 

 

80

Peripheral device write fault

A write operation to the disk media was terminated abnormally.

4, B

 

 

 

∙ Write current abnormality

 

 

 

 

 

 

 

82

Peripheral device write fault

A write operation to the disk media was terminated abnormally.

1, 3, B

 

 

 

∙ Servo mark not found during write.

 

 

 

 

 

 

 

83

Peripheral device write fault

A write operation to the disk media was terminated abnormally.

4, B

 

 

 

∙ Servo cell detected was detected during write.

 

 

 

 

∙ Write gate and sector pulse were activated at the same time

 

 

 

 

during write.

 

 

 

 

 

 

 

87

Peripheral device write fault

A write operation to the disk media was terminated abnormally.

1, 4, B

 

 

 

∙ No write gate detected

 

 

 

 

 

 

04

01

Logical unit in process of

Disk drive is getting ready.

2

 

 

becoming ready

(The spindle motor is not at its regular rotation speed or has

 

 

 

 

 

 

 

 

reached its regular rotation speed but is still reading the

 

 

 

 

information)

 

 

 

 

 

 

 

02

Logical unit not ready

Disk drive is in start command waiting state.

2

 

 

 

(initializing command required)

 

 

 

 

 

 

 

04

Logical unit not ready,

The drive cannot be accessed since it is being formatted.

2

 

 

format in progress

 

 

 

 

 

 

 

 

09

Logical unit not ready, Self-

The drive cannot be accessed since it is being Self-Test.

2

 

 

Test in progress

 

 

 

 

 

 

 

 

11

Logical unit not ready, Notify

The drive is in the Notify (ENABLE SPINUP) wait state.

2

 

 

(ENABLE SPINUP)

 

 

 

 

Required

 

 

 

 

 

 

 

0B

01

Specified temperature

Temperature exceeded established value.

0, 1, 6

 

 

exceeded

 

 

 

 

 

 

 

0C

01

Write error recovered with

A write error was recovered with auto reallocation.

1

 

 

auto reallocation

 

 

 

 

 

 

 

 

02

Write error – auto

Write auto reallocation or the write that was applied to auto

3

 

 

reallocation failed

reallocation was failed.

 

 

 

 

 

 

 

03

Write Error

Unrecovered Write Offtrack Error

3

 

 

 

∙ Write retries are exhausted in case of AWRE = 0

 

 

 

 

 

 

 

80

Write Error (Unrecovered

Reported if a write offtrack occurred during the Format unit

3

 

 

Write Offtrack Error)

command execution.

 

 

 

Write offtrack retries are

 

 

 

 

exhausted.

 

 

 

 

 

 

 

 

 

* C: Additional Sense Code, Q: Additional Sense Code Qualifier

 

C141-C013

365

Page 369
Image 369
Fujitsu MBA3073RC, MBC2036RC, MBC2073RC, MBA3300RC, MBA3147RC specifications Enable Spinup