4.2 Data Access Commands

4.2.7 SEEK (0B)

 

Bit

7

6

5

4

 

3

 

2

1

 

0

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

X'0B'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

0

0

0

 

Logical Block Address (MSB)

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

Logical Block Address

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

Logical Block Address (LSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

0

0

0

0

0

 

0

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

5

 

0

0

0

0

0

 

0

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

This command executes a seek operation of the cylinder/track where the logical data block specified in the "Logical block address" field in the CDB exists.

When disconnect processing is permitted, the HDD performs disconnect processing after receiving the CDB. After that, the HDD executes reconnect processing at the point when the seek operation is completed and reports the status.

When disconnect processing is not permitted, the HDD executes the seek operation while still connected to the FC interface and when it is completed, reports the status of this command.

C141-C013

221

Page 225
Image 225