Command Specifications

Table 4.52 SEND DIAGNOSTIC parameters: PHY Test function

Bit

7

6

5

 

4

3

 

2

1

 

0

Byte

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

X'3F' (page code)

 

 

 

 

 

 

 

 

 

 

 

 

 

1

0

0

0

0

X'6' (Protocol Identifier)

 

 

 

 

 

 

 

 

 

2-3

 

 

X'001C' (page parameter length)

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

PHY Identifier

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

PHY Test Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

PHY Test Pattern

 

 

 

 

 

 

 

 

 

 

7

0

0

0

0

PHY Test Pattern Physical Link Rate

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

X'0000' (Reserved)

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

PHY Test Pattern DWORD Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

PHY Test Pattern DWORDS

 

 

 

 

 

 

 

 

 

 

 

 

19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

X'0000' (Reserved)

 

 

 

 

 

 

 

 

 

 

 

 

 

31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Protocol Identifier Specify value (0x06).

If a value other than the above value is specified, HDD processing ends with a failure with CHECK CONDITION status "ILLEGAL REQUEST [=5]/ Invalid field in parameter list [=26-00]".

Page Parameter Length Specify value (0x001C).

If a value other than the above value is specified, HDD processing ends with a failure with CHECK CONDITION status "ILLEGAL REQUEST [=5]/ Invalid field in parameter list [=26-00]".

252

C141-C013

Page 256
Image 256
Fujitsu MBC2073RC, MBC2036RC, MBA3300RC, MBA3147RC, MBA3073RC specifications Send Diagnostic parameters PHY Test function