7.4 Background Media Scan (BMS)

EN_BMS (Enable Background Media Scan)

When this bit is set to "1," the Background Media Scan (BMS) function is enabled. Media scan processing will begin at the time determined by the BMS Interval Time (bytes 6-7) specification.

When this bit is cleared to "0," the BMS function is disabled. Clearing this bit to "0" while BMS media scan processing is in progress immediately suspends the media scan processing. Setting the bit back to "1" immediately resumes media scanning from the point of suspension.

EN_PS (Enable Pre-Scan)

When this bit is set to "1," the Pre-Scan function is enabled. Clearing this bit to "0" while Pre-Scan processing is in progress immediately suspends the scanning processing.

BMS Interval Time

Once Background Media Scan (including Pre-Scan) processing is started, the next Background Media Scan operation will begin after the time in hours specified in this field. When '0' is assigned to this field, the minimum value of '1' will be reported.

Pre-Scan Timeout Value

When the time in hours specified here elapses, Pre-Scan scanning processing ends, assuming a timeout.

Minimum IDLE TIME before Background Scan

Displays the time from IDLE status to start of BMS (unit: milliseconds). HDD ignors the values specified for this parameter and operates in accordance with the default value.

Maximum TIME to suspend Background Scan

Displays the maximum amount of time required until the execution of a command (unit: milliseconds) when a command is received during BMS operation. HDD ignores the value specified for this parameter and operates in accordance with the default value.