Fujitsu MBA3147RC, MBC2036RC, MBC2073RC, MBA3300RC, MBA3073RC specifications Sense Data

Models: MBA3300RC MBA3147RC MBA3073RC MBC2073RC MBC2036RC

1 439
Download 439 pages 37.87 Kb
Page 373
Image 373

6.1 Sense Data

Table 6.4 Additional Sense Code and Additional Sense Code Qualifier (5/6)

C*

Q*

Name

 

Explanation

Sense

 

key

 

 

 

 

 

 

 

 

 

 

44

nn

Internal target failure

An error was detected in self-diagnosis. ("nn" is a Fujitsu unique

4, B

 

 

 

code)

 

 

 

 

 

• 90:

Next sector HDD compare error

 

 

 

 

• 91:

WCS RAM parity error

 

 

 

 

• 92:

Unexpected FMT interrupt

 

 

 

 

• 94:

NRZ parity error during Write (MAS3*** Series only)

 

 

 

 

• 99:

Overflow error occurred at SPC FIFO

 

 

 

 

• 9A:

Error interrupt in the HDC

 

 

 

 

• A0:

Error interruption from DBM

 

 

 

 

• A3:

DBM buffer CRC error

 

 

 

 

• A4:

DBM internal parity error

 

 

 

 

• A8:

Data late error

4, B

 

 

 

• B0:

Flash ROM erase operation failed.

4

 

 

 

• B1:

Flash ROM write operation failed.

4

 

 

 

• C0:

RDCLK error (FMT hang up)

4

 

 

 

• D1:

DSP downloading failed

4

 

 

 

• D2:

DSP overrun (watch dog time out, DRV hard error)

4

 

 

 

• D3:

Servo Gate Window error

4

 

 

 

• D4:

Illegal error was reported from DSP

4

47

03

Information Unit iuCRC Error

An iuCRC error is detected on the SAS interface for a Data

B

 

 

Detected

frame.

 

 

 

 

 

4B

01

Invalid Target Port Transfer

An illegal TPTT is received.

B

 

 

Tag Received

 

 

 

 

 

 

 

 

02

Too Much Write Data

The Write Data frame is longer than the stipulated frame length.

B

 

03

ACK/NAK Timeout

A response to a XFER_RDY frame or Data frame has not been

B

 

 

detected for more than 1 ms.

 

 

 

 

 

04

NAK Received

A NAK primitive is received for a XFER_RDY frame or Data

B

 

 

frame.

 

 

 

 

 

 

 

05

Data Offset Error

A Relative Offset error is detected in a Write Data frame.

B

 

06

Initiator Response Timeout

A response to a Data frame has not been detected for the

B

 

 

 

"Initiator Response Timeout" in Mode Page 19.

 

 

 

 

4C

nn

Logical unit failed self-

The HDD's initial setup failed. ('nn' is a Fujitsu unique code)

4

 

 

configuration

• 91:

Microcode Read error (any 3/11/** error during

 

 

 

 

 

microcode read)

 

 

 

 

• 93:

Microcode Read error (any 3/13/** NOSB error)

 

 

 

 

• 94:

Microcode Read error (any 3/14/** NRF error)

 

 

 

 

• 95:

Microcode Read error (any 3/15/** error during seek)

 

 

 

 

• 97:

Microcode Read error (any 4/44/** or other errors

 

 

 

 

 

during microcode read)

 

 

 

 

• 98:

Invalid microcode (Header/Check Sum)

 

 

 

 

• A1:

SA Read error (any 3/11/** error during SA read)

 

 

 

 

• A3:

SA Read error (any 3/13/** error during SA read)

 

 

 

 

• A4:

SA Read error (any 3/14/** error during SA read)

 

 

 

 

• A5:

SA Read error (any 3/15/** error during SA read)

 

 

 

 

• A7:

SA Read error (any 4/44/** error during SA read)

 

 

 

 

• A8:

Invalid SA (Header/Check Sum)

 

 

 

 

• AA:

SA Read error (DSP overrun/DRV hardware error)

 

 

 

 

• AB:

SA Read error (abnormal rotation of spindle motor)

 

 

 

 

• AC:

SA Read error (on-track failure)

 

 

 

 

• E0:

Initial calibration failed

 

 

 

* C: Additional Sense Code,

Q: Additional Sense Code Qualifier

 

C141-C013