Command Specifications

PHY Test Pattern Physical Link Rate

Specify the Link Rate when INIT sends the PHY Test Pattern.

If a value other than any of the values below is specified, HDD processing ends with a failure with CHECK CONDITION status "ILLEGAL REQUEST [=5]/ Invalid field in parameter list [=26-00]".

8h: 1.5 Gbps

9h: 3.0 Gbps

PHY Test Pattern DWORDS Control

When the PHY Test Pattern is 40h, and a value other than 00h, 08h, 80h or 88h is specified, HDD processing ends with a failure with CHECK CONDITION status "ILLEGAL REQUEST [=5]/ Invalid field in parameter list [=26-00]".

When PHY Test Pattern is 01h or 02h, this field is ignored.

00h: The DWORD set in the PHY Test Pattern DWORDS field JTPAT is repeated and sent.

08h: For the DWORD set in the PHY Test Pattern DWORDS field JTPAT, the 12th Byte is encoded as the control character (k-code), repeated, and sent.

80h: For the DWORD set in the PHY Test Pattern DWORDS field JTPAT, the 16th Byte is encoded as the control character (k-code), repeated, and sent.

88h: For the DWORD set in the PHY Test Pattern DWORDS field JTPAT, the 12th Byte and 16th Byte are encoded as the control character (k-code), repeated, and sent.

PHY Test Pattern DWORDS

Specify the data sent when PHY Test Pattern = 40h applies.

254

C141-C013

Page 258
Image 258
Fujitsu MBA3147RC, MBC2036RC, MBC2073RC, MBA3300RC, MBA3073RC specifications Command Specifications