CHAPTER 6: IEEE 488 Primer

Device 1

System Controller

Able to Talk,

Listen, and Control

Device 2

DMM

Able to Talk and Listen

Device 3

Printer

Only Able to Listen

Device 4

Frequency Counter

Only Able to Talk

To Other Devices

Data Bus

Data Byte

Transfer

Control

General

Interface

Management

DIO1-8

DAV

NRFD

NDAC

IFC

ATN

SRQ

REN

EOI

Figure 6-1. IEEE 488 Bus Structure.

6.3 Send It to My Address

In the previous discussion, the terms “Addressed to Talk” and “Addressed to Listen” were used. These terms require some clarification.

The IEEE 488 standard permits up to 15 devices to be configured within one system. Each of these devices must have a unique address to avoid confusion. In a similar fashion, every building in town has a unique address to prevent one home from receiving another home’s mail. Exactly how each device’s address is set is specific to the device’s manufacturer. Some are set by DIP switches in hardware, others by software. Consult the manufacturer’s instructions to determine how to set the address.

Addresses are sent with universal (multiline) commands from the Active Controller. These commands include My Listen Address (MLA), My Talk Address (MTA), Talk Address Group (TAG), and Listen Address Group (LAG).

55

Page 55
Image 55
Black Box IC026AE-R2, IC026A-R2 manual Send It to My Address, Dmm