Specifications and Dimensions

NOTE: The heater shall be installed in a space large in comparison to the size of the heater. Large space is defined as having a volume at least sixteen (16) times the total volume of the heater.

Specifications and Dimensions

MODEL 0133

 

Indoor

Outdoor

 

 

 

 

 

 

Model

 

Recovery

Recovery

 

Number

Input MBH

GPH*

GPH*

NOTE:

WH-0133

136.0

135

132

Ratings are shown for elevations up to 2,000 feet. For elevations

over 2,000 feet, reduce ratings 4% for each 1,000 feet above sea

 

 

 

 

 

 

 

 

* Recovery based on manufacturer’s rating.

 

level.

MODELS 0182-0400 and 0181-0401

 

 

Indoor

 

Dimensions (in inches)

 

 

 

 

 

Width

Height

 

Flue

 

Input

 

Recovery

 

Diameter

Model Number

MBH

 

GPH*

A

C

J

K

WH-0182/0181

181.0

 

180

18-1/4

62-5/8

12-1/16

6

WH-0206/0261

264.0

 

262

22-3/8

62-7/8

11-1/8

7

WH-0330/0331

334.0

 

332

25-3/4

63-3/4

10-3/4

8

WH-0400/0401

399.0

 

397

29-1/4

65-3/8

12-1/2

9

 

 

 

 

 

 

 

 

* Recovery based on manufacturer’s rating.

NOTE:

Ratings are shown for elevations up to 2,000 feet. For elevations over 2,000 feet, reduce ratings 4% for each 1,000 feet above sea level.

Bold type indicates Low NOx models.