Tricity Bendix AW 1054 W installation instructions Electrical connection, Permanent connection

Page 27

Electrical connection

Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person.

WARNING: THIS APPLIANCE MUST BE EARTHED.

The manufacturer declines any liability should this safety measure not be observed.

Before switching on, make sure the electricity supply voltage is the same as that indicated on the appliance’s rating plate. The rating plate is located at the top of the rim of the open door.

 

Mod

 

Prod. No

P0042

Ser. No

 

The appliance is supplied with a 13amp plug fitted. In the event of having to change the fuse in the plug supplied, a 13amp ASTA approved (BS1363A) fuse must be used.

Should the plug need to be replaced for any reason, proceed as described below.

The wires in the mains lead are coloured in accordance with the following code:

Green and Yellow

- Earth

Blue- Neutral

Brown- Live

GREEN & YELLOW

E

The wire coloured brown must be connected to the terminal marked «L» or coloured red.

Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.

WARNING:

A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard.

Ensure that the cut off plug is disposed of safely.

Should the appliance power supply cable need to be replaced, this should be carried out by our Service Force Centre.

Note

When the appliance is installed the power supply cable must be accessible.

Permanent connection

In the case of permanent connection it is necessary that you install a double pole switch between the appliance and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current electrical regulations.

The switch must not break the yellow and green earth cable at any point.

N

13 A

L

BROWN

BLUE

P1041

CORD CLAMP

 

The wire coloured green and yellow must be connected to the terminal marked with the letter «E» or by the earth symbol or coloured green and yellow.

The wire coloured blue must be connected to the terminal marked «N» or coloured black.

27

Image 27
Contents AW 1054 W Installation Child SafetyUse Contents Your New Washing Machine Ecological hintsInterest Environment Detergent dispenser drawer Description of the ApplianceControl Panel Operating Sequence At the end of the programme Start the machineWashing 2 KG of Mixed Fabrics AT 50C At the end of the programme 1000g = 1 kg Washing HintsWhich form? Which detergent?Important Notes Wash Care SymbolsWashing Programmes Washing symbol Type of laundryProgrammes for synthetics, mixed fabrics, wool and delicates Maintenance and Cleaning Water inlet filters Something Not Working Customer Care Service & Spare PartsSymptom Possible causes 0870 5This guarantee does not cover Guarantee ConditionsStandard guarantee conditions European guaranteeWay 3AE Technical Specifications Installation InstructionsWater inlet Installation on a Suspended FloorUnpacking PositioningWater drainage Levelling Special conditionsInterest of the environment Permanent connection Electrical connectionConsumer care telephone number 08705