Chicago Electric 94702 Replacing the Cleaning Solution, Cleaning the Flexible Pipe

Page 9

Warning: Chlorinated solvents such as 1-1-1 Trichloroethane and Methylene Chloride (also known as Methyl Chloride) can chemically react with aluminum and may explode. Many tools and pieces of equipment contain aluminum.

1.Fill the Body (7) with the proper cleaning solution. Fill the Body (7) to just below the horizontal crease on the Body (7).

2.Lift the Cover (1) and place the tool(s) to be cleaned into the Work Basket (2) if possible. Set Work Basket (2) and/or tools into the cleaning solution.

3.Make sure the Power Switch (23) is in the OFF position before plugging in the Parts Washer. When the Power Switch (23) is ON, the light in the switch will be lit up.

4.Plug the Parts Washer Electrical Cord into a grounded, 120 Volt, electrical outlet. Turn on the Parts Washer, making certain that the Power Switch (23) is lit up.

5.Once the tool is clean, press the Power Switch (23) to the OFF position. Unplug the Electrical Cord.

6.Remove the tool from the cleaning fluid and air dry or wipe them clean with a clean cloth.

7.Close the Cover (1) of the Parts Washer.

Replacing the Cleaning Solution

1.Make certain that the Parts Washer is OFF and that the Electric Cord is unplugged from the electrical outlet before performing any maintenance.

2.Place an empty container onto the Shelf directly below the Plug (11) and O-Ring (10). Make certain that the container is large enough to hold all of fluid that will drain from the Body (7).

3.Unscrew the Plug (11) from underneath the Body (7). Make certain the fluid is draining directly into the container.

4.Dispose of the used cleaning solution properly. Do not drain the cleaning solution into the street drains, house drains or into the earth. Contact your local municipal waste management officials for proper disposal methods.

5.Replace the Plug (11).

Cleaning the Flexible Pipe

1.Make certain that the Parts Washer is OFF and that the Electric Cord is unplugged from the electrical outlet before performing any maintenance.

2.Remove the Flexible Pipe (24) from the Elbow (26). Drain the pipe, inspect its interior for debris. Use compressed air to blow clean.

3.Reattach the Flexible Pipe (24) to the Elbow (26).

SKU 94702

For technical questions please call 1-800-444-3353.

Page 9

Image 9
Contents 94702 General Safety Rules Read and Understand ALL Instructions Technical SpecificationsModel Serial No. Purchase Date Work AreaPersonal Safety Electrical SafetyTool USE and Care ServiceGrounding Grounded Tools Tools with Three Prong PlugsExtension Cords Double Insulated Appliances Appliances with TWO Prong PlugsSymbology Specific Safety Rules Forthe 20 Gallon Partswasher Unpacking AssemblyCleaning the Flexible Pipe Replacing the Cleaning SolutionDescription Quantity Parts ListLimited 90 DAY Warranty