ADC ML-96 service manual

Page 41

6.bURNER CONTROL FAIL- This routine monitors the ignition control’s gas valve output response. If the valve output signal is not present from the ignition control within the valve time limits the Phase 6 microprocessor controller (computer) determines the ignition control has failed. If this occurs when the cycle is active the machine will display “bURNER CONTROL FAIL.” If the tumbler temperature is above 100º F (38º C) the machine will continue to display “bURNER CONTROL FAIL.” The machine will run with no heat for three (3) minutes or until the temperature drops below 100º F (38º C). If the tumbler temperature is below 100º F (38º C) upon failure the machine will shut down and display “bURNER CONTROL FAIL” with an audio indication.

7.bURNER FLAME FAIL- This routine allows two (2) flame out retries to occur before proceeding into the error. The count of two (2) will be established every time the call for heat was to occur. Only if it reaches the count of two (2) before the tumbler temperature has reached the set temperature will this error be triggered. The machine will run with no heat for three (3) minutes or until the temperature drops below 100º F (38º C). If the tumbler temperature is below 100º F (38º C) upon failure, the machine will shut down and display "bURNER FLAME FAIL" with an audio indication. This process will occur every time the heat output is active.

8.MAIN DOOR- This monitors the door circuit. If the machine was not active and the main door was opened the display would read “REAdY.” If a program attempt was made with the main doors open the display will read "MAIN dOOR" with an audio indication. If the machine is active and the main door was opened the display would read “MAIN dOOR” with no audio indication and the dryer will shut down. Once the main door has closed the display would read “PRESS START” press the “ENTER/START” key and it will continue the programmed cycle.

9.LINT dOOR- This monitors the lint drawer and door circuit. If the machine was not active and the lint drawer and door was opened the display would read “REAdY.” If a program attempt was made with the lint drawer and door open the display would read “LINT dOOR” with an audio indication. If the machine is active and the lint drawer and door was opened the display would read “LINT dOOR” with no audio indication and the dryer will shut down. Once the lint door was closed the display would read “PRESS START” press the “ENTER/START” key and it will continue the programmed cycle.

10.TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE- This routine monitors the tumbler temperature. When the temperature sensor or fuse opens with the machine not active the display will read “TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE” with an audio indication. If the machine was active at the time that the temperature sensor or fuse opened the display would read “TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE.” If the tumbler temperature is above 100º F (38º C) the machine will continue to display “TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE” with an audio indication and run with no heat for three (3) minutes or until the temperature drops below 100º F (38º C). If the tumbler temperature is below 100º F (38º C) upon failure the machine will shut down and display “TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE” with an audio indication. The display will continue to read “TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE” an audio indication will sound for approximately 5 seconds, every 30 seconds until the problem is corrected or the power to the dryer is disconnected (and the problem is corrected).

NOTE: Once the Phase 6 microprocessor controller (computer) detects a problem in the heat circuit, it updates every 30 seconds, so that if the problem was a loose connection in the circuit which corrected itself, the “TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE” condition would automatically be cancelled and the display will return to “REAdY.”

37

Image 41
Contents ML-96 Retain This Manual In a Safe Place For Future Reference For Your Safety Page Table of Contents Section Important Information Safety PrecautionsPage MATERIALS, Gasoline and Other Flammable Vapors Routine MaintenanceCleaning Lubrication AdjustmentsElectrical and GAS Requirements Installation RequirementsENCLOSURE, AIR SUPPLY, and Exhaust Requirements Operational Service Check Procedure Page Reversing Relay Panel Description of PartsDrive Motor GAS Burner AssemblyHSI HOT Surface Ignition Module Gas Models Only Tumbler Basket Drive Shaft AssemblyIdler Shaft Assembly Burner HI-LIMIT Gas Models Only Main Door SwitchSail Switch Gas Models Only Lint Screen Manual Reset ThermostatLint Drawer Switch Introduction Computer Board ReplacementServicing Microprocessor Temperature Sensor Probe Replacement Keyboard Touchpad Label Assembly ReplacementHot Surface Ignitor Flame Sensor Probe Flame Sensor Probe ReplacementIgnition Controls Main Burner Orifices Replacement Gas Valve Replacement Refer to burner illustration onTo Convert Natural Gas to L.P. Gas To Test and Adjust Gas Water Column PressureHSI Hot Surface Ignition Module Replacement Burner Tubes ReplacementDisconnect electrical power to the dryer Open lint door To Adjust Sail Switch Sail Switch Assembly Gas Models OnlySail Switch Replacement To Install New Main Door Glass Main Door Assembly ReplacementMain Door Hinge Block Replacement Front Panel ReplacementDrive Motor Pulley Replacement Drive Shaft Pulley ReplacementPage 15/16 Flange Bearing Replacement Basket AssemblyRotational Sensor Assembly Belt Adjustment Motor to Drive Axle Idler Shaft Pillow Block Bearing ReplacementDrive Shaft Pillow Block Bearing Replacement Motors Drive Motor V-Belts ReplacementDrive Motor Replacement Lint Door Switch Replacement Motorized Impellor Blower ReplacementComputer will not accept keypad touchpad entries TroubleshootingDryer operates but is taking too long to dry Overload for impellor fan motor is tripping Burner hi-limit safety thermostat is trippingThermal overload for drive motor is tripping There is excessive vibration coming from the tumbler basket Diagnostic L.E.D. Light Emitting Diode Display Failure Codes Phase 6 OPL System DiagnosticsPage E.D. Display Indicator Number E.D. Light Emitting Diode Display IndicatorsE.D. Display Indicator Number HT1 Heat Output L.E.D. light emitting diode Indicator FAN Blower Output L.E.D. light emitting diode IndicatorMain Main Door Input L.E.D. light emitting diode Indicator Fuse Main Fuse Input L.E.D. light emitting diode IndicatorLint Lint Door Input L.E.D. light emitting diode Indicator Power Supply Input L.E.D. light emitting diode Indicator E.D. Codes 1. Display Codes GAS only Ignition Attempt Failure GAS Models only Power 24 VAC is not Evident AT GAS ValveGAS/ELECTRIC only BURNER/OVEN Open HI-LIMIT Circuit Computer Logic and Wiring Diagram Page Drive motor reverses but does not forward, blower motor runs No Display ConditionLint Door Condition Blower motor does not operate, drive motor runsMicroprocessor Computer Main Door ConditionFor Phase 6 Models Manual Reset HI-LIMIT InstructionsMotor Plate High and LOW Voltage Technical InformationInformation on the Data Label Data LabelHOW to USE a Manometer ML-96 Tool List ADC450406 1- 02/09/00-25
Related manuals
Manual 26 pages 45.33 Kb

ML-96 specifications

The ADC ML-122 and ML-96 are two advanced communication devices designed for efficient data collection and transmission in various applications. Both models are renowned for their robust performance and user-friendly features, which cater to a diverse range of industries.

The ADC ML-122 is a high-performance data logger that excels in multi-channel monitoring. It supports various input types, making it versatile for applications such as environmental monitoring, industrial process control, and research. One of its standout features is its ability to accommodate both analog and digital signals, allowing users to gather a wealth of data from different sources. The device supports a wide temperature range, ensuring reliability in diverse environmental conditions. Moreover, its built-in memory can store extensive data logs, which are easily downloadable for analysis.

On the other hand, the ADC ML-96 is designed primarily for telecommunication and network monitoring. It features advanced signal processing technologies that allow it to analyze and troubleshoot communication lines efficiently. The device is equipped with real-time monitoring capabilities, enabling users to detect issues as they arise, which is crucial in maintaining network integrity. The ML-96's compact design makes it an ideal choice for installation in tight spaces without sacrificing performance.

Both models are built with cutting-edge technologies that enhance their functionality. They integrate wireless communication protocols, such as Wi-Fi and Bluetooth, enabling seamless connectivity to cloud services for data backup and remote access. This feature empowers users to monitor conditions from anywhere, ensuring that critical information is always at hand.

The user interface for both the ML-122 and ML-96 is designed for ease of use. Equipped with a clear display and intuitive controls, users can navigate through settings and view data with minimal training. The devices also offer customizable alerts that notify users of any anomalies, adding an additional layer of security and responsiveness.

In terms of power management, both models utilize energy-efficient components, allowing for extended battery life. This is particularly advantageous in remote sensing applications where power sources may be limited. Furthermore, the ability to integrate with other systems makes these models adaptable to various operational needs.

In conclusion, the ADC ML-122 and ML-96 stand out in their respective markets due to their innovative features, reliable technologies, and user-friendly designs. With their flexibility and performance, they continue to set the standard for data logging and communication monitoring technologies.