Speed Queen 30 lb, 25 lb, 80 lb, 60 lb, 40 lb manual Washer-Extractor Specifications

Page 6

Washer-Extractor Specifications

 

 

 

SC20

SC25

SC30

SC40

SC60

SC80

 

 

 

 

 

 

 

 

 

Capacity - lb (kg)

 

20 (9)

25 (11.3)

30 (13.6)

40 (18)

60 (27)

80 (36)

 

 

 

 

 

 

 

 

 

Width - in (mm)

 

26” (660)

26” (660)

29” (737)

30 5/8” (778)

34 1/16” (865)

41 1/2” (1054)

 

 

 

 

 

 

 

 

 

Depth - in (mm)*

 

29 11/16” (754)

33 11/16” (856)

35” (889)

40” (1016)

42 4/5” (1086)

51 5/8” (1312)

 

 

 

 

 

 

 

 

 

Height - in (mm)

 

42” (1067)

45” (1143)

45” (1143)

47 1/4” (1200)

50” (1269)

56” (1422)

 

 

 

 

 

 

 

 

 

Cylinder Diameter - in (mm)

 

21” (533)

21” (533)

24” (610)

26 1/4” (667)

30” (762)

36” (914)

 

 

 

 

 

 

 

 

Cylinder Volume - cu. ft. (liters)

2.8 (78.1)

3.8 (106)

4.2 (118)

6.3 (180)

9.0 (255)

13 (368)

 

 

 

 

 

 

 

 

 

Door Opening Size - in (mm)

 

12” (305)

12” (305)

14 11/32” (364)

16 1/4” (413)

16 1/4” (413)

18 1/2” (470)

Door Bottom to Floor - in (mm)

14 3/8” (366)

14 3/8” (366)

14” (356)

14 1/2” (368)

13 1/2” (343)

17 5/8” (451)

 

 

 

 

 

 

 

 

 

G-Factor(High Extract)

 

82

87

78

82

86

40/85/142

 

 

 

 

 

 

 

 

 

Wash Speed - rpm

 

53

55

47

47

44

22/40

High Extract - rpm

 

525

540

480

470

450

280/408/524

 

 

 

 

 

 

 

 

 

Water Inlet Conn. - in (mm)

 

3/4” (19)

3/4” (19)

3/4” (19)

3/4” (19)

3/4” (19)

3/4” (19)

 

 

 

 

 

 

 

 

 

Drain Diameter - in (mm)

 

2” (52)

2” (52)

2” (52)

3” (76)

3” (76)

3” (76)

 

 

 

 

 

 

 

 

Drain Height to Floor - in (mm)

4 3/8” (111)

4 3/8” (111)

4” (102)

4 3/4” (121)

3 1/2” (89)

5 3/4” (146)

 

 

 

 

 

 

 

 

 

Motor HP (wash) - HP (kW)

 

.18 (.13)

.25 (.19)

.25 (.19)

.40 (.30)

.55 (.41)

N/A

Motor HP (extract) - HP (kW)

 

1.0 (.75)

1.4 (1.04)

1.4 (1.04)

1.8 (1.3)

2.7 (2.01)

5 (3.7)

 

 

 

 

 

 

 

 

 

Voltage/Hz/Phase**

 

B

110-120/60/120-15

N/A

N/A

N/A

N/A

N/A

Circuit Breaker-FLA amp

 

C

380-415/50/315-4

380-415/50/315-4

380-415/50/315-4

380-415/50/315-5

380-415/50/315-4

N/A

 

 

D

220-240/50/315-5

220-240/50/315-6

220-240/50/315-6

220-240/50/320-7.5

220-240/50/320-7

N/A

 

 

E

220-240/50/120-10

220-240/50/120-10

220-240/50/120-10

N/A

N/A

N/A

 

 

F

440-480/60/315-4

N/A

N/A

N/A

N/A

N/A

 

 

H

380/60/3 • 15-4.8

380/60/3 • 15-4.8

380/60/3 • 15-4.8

380/60/3 • 15-4.8

380/60/3 • 15-3

N/A

 

 

J

220/50/3 • 20-7.5

220/50/3 • 20-7.5

220/50/3 • 20-7.5

220/50/3 • 20-7.5

220/50/3 • 20-8

N/A

 

 

N

N/A

N/A

N/A

N/A

N/A

440-480/50-60/315-4.5

 

 

O**

220-240/60/315-5

220-240/60/315-6

220-240/60/315-7

220-240/60/320-7.5

220-240/60/320-7

N/A

 

 

P

N/A

N/A

N/A

N/A

N/A

380-415/50-60/315-4.5

 

 

Q**

N/A

N/A

N/A

N/A

N/A

200-240/50-60/320-12.4

 

 

X

N/A

N/A

N/A

N/A

220-240/50-60/1-320-9

N/A

 

 

Y

208-240/60/120-10

208-240/60/120-10

208-240/60/120-10

208-240/60/120-13.5

N/A

N/A

Shipping Dimensions -

 

H

51” (1295)

53 1/2” (1359)

53 1/2” (1359)

56 1/2” (1422)

58 1/2” (1486)

62 1/2” (1588)

in (mm)

 

W

29” (737)

29” (737)

30 1/2” (775)

32” (813)

36” (914)

48” (1219)

 

 

D

32 1/2” (826)

36 1/4” (921)

37 1/2” (953)

41” (1041)

44 1/2” (1130)

56” (1422)

Net Weight - lb (kg)

 

390 (177)

435 (198)

495 (225)

706 (321)

767 (348)

1406 (633)

 

 

 

 

 

 

 

 

 

Shipping Weight - lb (kg)

 

410 (186)

470 (214)

535 (243)

744 (338)

818 (371)

1456 (655)

 

 

 

 

 

 

 

 

Export Shipping Weight - lb (kg)

480 (218)

530 (241)

601 (273)

846 (385)

997 (452)

1506 (678)

 

 

 

 

 

 

 

 

Agency Approvals***

 

CE, ETL, ETLc

CE, ETL, ETLc

CE, ETL, ETLc

CE, ETL, ETLc

CE, ETL, ETLc

CE, ETL, ETLc

 

 

 

 

 

 

 

 

 

*Overall depth includes drain pipe and door handle.

**Standard domestic voltage 208–240/60/3. Circuit breaker and amp draw data shown is for standard voltage models without auxiliary heat. Consult factory for other configurations. Manufacturer strongly recommends using a circuit breaker instead of fuses. Use 3-pole circuit breakers for 3-phase machines. All CE approved models available in 50 hz 20-60 models.

***Agency approvals may vary depending on configuration. Consult factory for details. Steam connection requires 1/2” N.P.T.

Due to continuous product improvements, design and specifications subject to change without notice. The quality management systems at all Alliance Laundry Systems facilities are registered as ISO 9001:2000 compliant.

©Copyright 2004 Alliance Laundry Systems LLC

®

www.speedqueen.com

AC04-216

Image 6
Contents Qwert Let Speed Queen Lead the Way Heavy Duty Construction Door Lock DelaySuperior Serviceability Large Door OpeningControl Options Through three years Through five yearsWasher-Extractor Specifications