BladeCenter HS40 specifications for NEBS/ETSI environments

BladeCenter HS40 specifications for NEBS/ETSI environments

The following table provides a summary of the features and specifications of the BladeCenter T HS40 Type 8839 blade server operating in a NEBS/ETSI environment.

Note: Power, cooling, removable-media drives, external ports, and advanced system management are provided by the IBM Eserver BladeCenter T Type

8720.

Microprocessor:

Supports up to 4 microprocessors

vIntel Xeon 2.0 GHz or faster

vL2 and L3 caches, size dependant on microprocessor

Memory:

vEight double data rate (DDR) PC2100 184-pin DIMM sockets

vMinimum: 512 MB

vMaximum: 16 GB1

vType: 2-way interleaved, DDR, PC2100, ECC SDRAM registered x4 (Chipkill) dual inline memory modules (DIMMs) only

vSupports 256 MB, 512 MB, 1 GB, and 2 GB DIMMs

vHot Spare memory

Expansion:

Two I/O expansion card connectors

Drives:

Support for up to two Ultra320 SCSI hot-swap hard disk drives available in an optional SCSI storage expansion unit

Size:

vHeight: 24.5 cm (9.7 inches)

vDepth: 44.6 cm (17.6 inches)

vWidth: 5.9 cm (2.32 inches)

vMaximum weight: 7.0 kg (15.4 lb)

Integrated functions:

vFour Gigabit Ethernet controllers

vATI Radeon 7000 video controller

vLight path diagnostics

vLocal service processor

vIDE hard disk drive controller (the IDE controller is reserved for future use and is not available for this server type)

vRS-485 interface for communication with management module

vIntegrated Baseboard Management Controller

vUniversal Serial Bus (USB) v1.1 for communication with keyboard, mouse, diskette drive, and CD-ROM drive2

vSerial over LAN (SOL) management interface

Electrical input:

Input power: 400 W, maximum

Predictive Failure Analysis (PFA) alerts:

vMicroprocessor

vMemory

vHard disk drives

Environment (NEBS):

vAir temperature:

Blade server on: 5° to 40°C (41°

to 104°F). Altitude: -60 to 1800 m (-197 to 6000 ft)

Blade server on (short term): -5° to 55°C (23° to 131°F) Altitude: -60 to 1800 m (-197 to 6000 ft)

Blade server on: 5° to 30°C (41°

to 86°F). Altitude: 1800 to 4000 m (6000 to 13 000 ft)

Blade server on (short term): -5° to 45°C (23° to 113°F). Altitude: 1800 to 4000 m (6000 to 13 000 ft)

Blade server off: -40° to 70°C (-40° to 158°F)

vHumidity:

Blade server on: 5% to 80%

Blade server on (short term): 5% to 90% but not to exceed 0.024 kg water/kg of dry air

Blade server off: uncontrolled

Note: Short termrefers to a period of not more than 96 consecutive hours and a total of not more than 15 days in 1 year. (This refers to a total of 360 hours in any given year, but no more than 15 occurrences during that 1-year period.)

Notes:

1.You might have to enable large-memory support for your operating system to access all of the memory that is installed in your blade server. See the documentation for your operating system for information.

2.The operating system in the blade server must provide USB support for the blade server to recognize and use the keyboard, mouse, CD-ROM drive, and an external diskette drive. The BladeCenter T unit uses USB for internal communications with these devices.