IBM HS40 manual

Models: HS40

1 172
Download 172 pages 19.46 Kb
Page 92
Image 92
Manual background

Note: See Chapter 7, “Parts listing, Type 8839,” on page 105 to determine which components should be replaced by a field service technician.

Error code/symptom

FRU/action

 

 

 

84F2

1.

Update the BMC and SDRs with the most current versions that

(Server management interface failed)

 

are compatible with your system configuration.

 

 

 

2.

I/O board.

 

 

 

84F3

1.

The BMC recovery jumper is in the active position and the BMC

(BMC in update mode)

 

can be updated.

 

 

 

2.

After updating the BMC, move the jumper to the inactive position.

 

 

 

84F4

1.

Update the BMC and SDRs with the most current versions that

(Sensor Data Record empty)

 

are compatible with your system configuration.

 

 

 

2.

I/O board.

 

3.

Processor board.

 

 

84FF

Clear the System Event Log.

(System Event Log full)

 

 

 

 

 

00150900

1.

PCI-X adapter

(SERR/PERR detected on PCI bus.)

2.

I/O board

 

 

 

 

00151730

1.

DIMM

(IMB parity/CRC error)

2.

Processor board

 

 

 

 

The following errors appear on the screen during POST and in the management-module error log.

Note: See Chapter 7, “Parts listing, Type 8839,” on page 105 to determine which components should be replaced by a field service technician.

Error code/symptom

FRU/action

 

 

 

Microprocessor 1 internal error (IERR)

1.

Run the Configuration/Setup Utility program, and enable the

 

 

 

microprocessor retest.

 

2.

Microprocessor 1.

 

3.

Processor board.

 

 

 

Microprocessor 2 internal error (IERR)

1.

Run the Configuration/Setup Utility program, and enable the

 

 

 

microprocessor retest.

 

2.

Microprocessor 2.

 

3.

Processor board.

 

 

 

Microprocessor 3 internal error (IERR)

1.

Run the Configuration/Setup Utility program, and enable the

 

 

 

microprocessor retest.

 

2.

Microprocessor 3.

 

3.

Processor board.

 

 

 

Microprocessor 4 internal error (IERR)

1.

Run the Configuration/Setup Utility program, and enable the

 

 

 

microprocessor retest.

 

2.

Microprocessor 4.

 

3.

Processor board.

 

 

 

82BladeCenter HS40 Type 8839: Hardware Maintenance Manual and Troubleshooting Guide

Page 92
Image 92
IBM HS40 manual