Note: See Chapter 7, “Parts listing, Type 8839,” on page 105 to determine which components should be replaced by a field service technician.
Power problems
Symptom | FRU/action | ||
|
|
| |
Power switch does not work | 1. | Reseat connector. | |
and reset button, if | |||
2. Front bezel with customer card. | |||
supported, does work. | |||
3. | System board. | ||
| |||
|
|
| |
The blade server does not | 1. | Make sure that: | |
turn on. | |||
| a. The power LED on the front of the BladeCenter unit is on. | ||
|
| ||
|
| b. The LEDs on all the BladeCenter power modules are on. | |
|
| c. If the blade server or attached storage expansion unit is in blade bay | |
|
| power modules are in power bays 1, 2, 3 and 4. | |
|
| d. The | |
|
| v If the power LED is blinking rapidly and continues to do so, the blade | |
|
| server is not communicating with the management module; reseat the | |
|
| blade server, then go to step 3 | |
|
| v If the power LED is off, the blade bay is not receiving power, the blade | |
|
| server is defective, or the LED information panel is loose or defective. | |
|
| e. Local power control for the blade server is enabled (use the BladeCenter | |
|
| management module Web interface to verify), or the blade server was | |
|
| instructed through the management module (Web interface or IBM Director) | |
|
| to turn on. | |
| 2. If you just installed an option in the blade server, remove it, and restart the | ||
|
| blade server. If the blade server= now turns on, you might have installed more | |
|
| options than the power to that blade bay supports. | |
| 3. Try another blade server in the blade bay; if it works, replace the faulty blade | ||
|
| server. | |
| 4. See “Undetermined problems” on page 101. | ||
|
| ||
The blade server does not | The microprocessor with the lowest feature set must be used as the startup | ||
turn on and the following | microprocessor (microprocessor 1; see “Processor board components” on | ||
conditions are present: | page 35). Move the microprocessor in location U66 to location U70, and move the | ||
1. The amber system error | microprocessor in location U70 to location U66. | ||
|
| ||
LED on the Blade Center |
|
| |
unit system LED panel is lit; |
|
| |
2. The amber blade error LED |
|
| |
on the blade server LED |
|
| |
panel is lit; and |
|
| |
3. The system error log |
|
| |
contains the message |
|
| |
″CPUs mismatched″. |
|
| |
|
|
| |
The blade server turns off for | 1. Make sure that all blade bays have a blade server, expansion unit, or filler | ||
no apparent reason | |||
| blade properly installed. If these components are missing or improperly | ||
|
| ||
|
| installed, an | |
| 2. If microprocessor LED is illuminated, replace the microprocessor. | ||
|
|
| |
The blade server does not | 1. Determine whether you are using an ACPI or | ||
turn off. | |||
| If you are using a | ||
|
| ||
|
| a. Press Ctrl+Alt+Delete. | |
|
| b. Turn off the system by holding the | |
|
| c. If computer fails during BIOS POST and | |
|
| work, remove the blade server from the bay and reseat it. | |
| 2. If the problem remains or if you are using an | ||
|
| suspect the system board. | |
|
|
|
94BladeCenter HS40 Type 8839: Hardware Maintenance Manual and Troubleshooting Guide