IBM HS40 manual SCSI error codes, Temperature error messages, Power error messages

Models: HS40

1 172
Download 172 pages 19.46 Kb
Page 107
Image 107
SCSI error codes

SCSI error codes

Error code

FRU/action

All SCSI Errors One or more of the

Make sure that the SCSI devices are configured correctly.

following might be causing the problem:

 

vA failing SCSI device (adapter, drive)

vAn improper SCSI configuration

vDuplicate SCSI IDs in the same SCSI chain

Temperature error messages

Note: See Chapter 7, “Parts listing, Type 8839,” on page 105 to determine which components should be replaced by a field service technician.

Message

Action

 

 

 

System over temperature for CPU x.

1.

Ensure that the system is being properly cooled; see “System

 

 

 

reliability considerations” on page 33.

 

2.

Replace microprocessor x.

 

 

 

Blade Storage Expansion option over

1.

Ensure that the system is being properly cooled; see “System

recommended temperature.

 

reliability considerations” on page 33.

 

 

 

2.

Replace the SCSI hard disk drives.

 

3.

Replace the Blade Storage Expansion option.

 

 

 

CPU x over temperature.

1.

Ensure that the system is being properly cooled; see “System

 

 

 

reliability considerations” on page 33.

 

2.

Replace microprocessor x.

 

 

 

Power error messages

Note: See Chapter 7, “Parts listing, Type 8839,” on page 105 to determine which components should be replaced by a field service technician.

Message

Action

 

 

 

BSE +12V over recommended voltage

1.

Check BladeCenter power (see IBM BladeCenter Type 8677

 

 

 

Hardware Maintenance Manual and Troubleshooting Guide).

 

2.

Reseat blade storage expansion option.

 

3.

Replace blade storage expansion option.

 

 

 

BSE +12V under recommended voltage

1.

Check BladeCenter power (see IBM BladeCenter Type 8677

 

 

 

Hardware Maintenance Manual and Troubleshooting Guide).

 

2.

Reseat blade storage expansion option.

 

3.

Replace blade storage expansion option.

 

 

 

BSE +5V over recommended voltage

1.

Check BladeCenter power (see IBM BladeCenter Type 8677

 

 

 

Hardware Maintenance Manual and Troubleshooting Guide).

 

2.

Reseat blade storage expansion option.

 

3.

Replace blade storage expansion option.

 

 

 

Chapter 6. Symptom-to-FRU index 97

Page 107
Image 107
IBM HS40 manual SCSI error codes, Temperature error messages, Power error messages