PrOBleM SyMPTOMS reSOlUTION
Excessive air tank
pressure – safety
valve pops off
Pressure switch does not
shut of motor when com-
pressor reaches cut-out
pressure
Pressure switch cut-out
too high
Set the On/Off switch to Off, if the unit
does not shut off contact a Bosch fac-
tory service center or a Bosch authorized
service center
Contact a Bosch factory service center or a
Bosch authorized service center
Air leaks Tube ttings are not tight
enough
Tighten ttings where air can be heard
escaping. Check ttings with soapy water
solution. Do not overtighten.
Air leaks in air tank or
at air tank welds
Defective air tank Air tank must be replaced. Do not repair
the leak
Warning: Risk of bursting. Do not drill into,
weld or otherwise modify air tank or it will
weaken. The air tank can rupture or ex-
plode.
Air leaks between
head and valve plate
Leaking seals Contact a Bosch factory service center or a
Bosch authorized service center
Air leaks from safety
valve
Defective safety valveOperate safety valve manually by pulling on
ring. If valve still leaks, it must be replaced.
Knocking noise Defective safety valve
Pump oil is low
Carbon build-up in pump
Operate safety valve manually by pulling on
ring. If valve still leaks, it must be replaced.
Add 30W non detergent oil to pump.
Contact a Bosch factory service center or a
Bosch authorized service center
Pressure reading on
the regulated pres-
sure gauge drops
when an accessory
is used
Regulator is not adjusted
correctly for accessory
being used
It is normal for some pressure drop to oc-
cur when an accessory is used, adjust the
regulator.
note: Adjust the regulated pressure under
ow conditions while accessory is being
used.
TROUBLE SHOOTING
This section provides a list of the more frequently encountered malfunctions, their causes and correc-
tive actions. The operator or maintenance personnel can perform some corrective actions, and others