Note: See Chapter 7, “Parts listing, Type 8839,” on page 105 to determine which components should be replaced by a field service technician.

Error code/symptom

FRU/action

 

 

 

196

1.

Microprocessor

(Processor cache mismatch detected)

2.

Processor board

 

 

 

 

198

1.

Microprocessor

(Processor speed mismatch detected)

2.

Processor board

 

 

 

 

289

1.

Run the Configuration/Setup Utility program.

(Non-matching or missing DIMMs, user

2.

Disabled DIMM.

has not installed DIMMs correctly, or

3.

System board

DIMM disabled by POST or user)

 

 

 

8120

1.

Check cooling.

(Microprocessor 1 thermal trip error)

2.

Replace blowers if needed.

 

 

3.

Run the Configuration/Setup Utility program, and enable the

 

 

processor retest.

 

4.

Microprocessor 1.

 

 

 

8121

1.

Check cooling.

(Microprocessor 2 thermal trip error)

2.

Replace blowers if needed.

 

 

3.

Run the Configuration/Setup Utility program, and enable the

 

 

processor retest.

 

4.

Microprocessor 2.

 

 

 

8122

1.

Check cooling.

(Microprocessor 3 thermal trip error)

2.

Replace blowers if needed.

 

 

3.

Run the Configuration/Setup Utility program, and enable the

 

 

processor retest.

 

4.

Microprocessor 3.

 

 

 

8123

1.

Check cooling.

(Microprocessor 4 thermal trip error)

2.

Replace blowers if needed.

 

 

3.

Run the Configuration/Setup Utility program, and enable the

 

 

processor retest.

 

4.

Microprocessor 4.

 

 

 

8130

1.

Run the Configuration/Setup Utility program, and enable the

(Microprocessor 1 disabled)

 

processor retest.

 

 

 

2.

Microprocessor 1.

 

 

 

8131

1.

Run the Configuration/Setup Utility program, and enable the

(Microprocessor 2 disabled)

 

processor retest.

 

 

 

2.

Microprocessor 2.

 

 

 

8133

1.

Run the Configuration/Setup Utility program, and enable the

(Microprocessor 3 disabled)

 

processor retest.

 

 

 

2.

Microprocessor 3.

 

 

 

8134

1.

Run the Configuration/Setup Utility program, and enable the

(Microprocessor 4 disabled)

 

processor retest.

 

 

 

2.

Microprocessor 4.

 

 

 

8140

1.

Run the Configuration/Setup Utility program, and enable the

(Microprocessor 1 failed FRB-3 timer)

 

processor retest.

 

 

 

2.

Microprocessor 1.

 

 

 