001 COMPLETE THE FOLLOWING STEPS TO PERFORM THE CHECKOUT
PROCEDURE.
1.Turn off the server and all external devices, if any are attached.
2.Check all cables and power cords.
3.Set all display controls to the middle position.
4.Turn on all external devices.
5.Turn on the server.
6.Record any POST error messages that are displayed on the screen. If an error is displayed, look up the first error in “POST error codes” on page 79.
7.Check the information LED panel blade error LED; if it is lit, see “Diagnosing problems using the light path diagnostics feature” on page 27.
8.Check the
9.Start the diagnostic programs.
10.Check for the following responses:
vOne beep
vReadable instructions or the main menu
002 DID YOU RECEIVE BOTH OF THE CORRECT RESPONSES?
NO. Find the failure symptom in Chapter 6,
YES. Run the diagnostic programs. If necessary, see “Diagnostic programs and error messages” on page 25.
If you receive an error, see Chapter 6,
If the diagnostic programs were completed successfully and you still suspect a problem, see “Undetermined problems” on page 101.
Diagnostic tools overview
The following tools are available to help you diagnose and solve
vBeep codes and error messages
The beep codes indicate that the
vDiagnostic programs and error messages
Real Time Diagnostics tests the major components of the BladeCenter unit, including the managemente modules, switch modules,
Notes:
1.As of the date of this document, the IBM Director CD does not come with the
BladeCenter T unit. If you have the BladeCenter T unit, see the IBM
Eserver BladeCenter HS40 Type 8839 Installation and User’s Guide for more information.
22BladeCenter HS40 Type 8839: Hardware Maintenance Manual and Troubleshooting Guide