001 COMPLETE THE FOLLOWING STEPS TO PERFORM THE CHECKOUT

001 COMPLETE THE FOLLOWING STEPS TO PERFORM THE CHECKOUT

PROCEDURE.

1.Turn off the server and all external devices, if any are attached.

2.Check all cables and power cords.

3.Set all display controls to the middle position.

4.Turn on all external devices.

5.Turn on the server.

6.Record any POST error messages that are displayed on the screen. If an error is displayed, look up the first error in “POST error codes” on page 79.

7.Check the information LED panel blade error LED; if it is lit, see “Diagnosing problems using the light path diagnostics feature” on page 27.

8.Check the system-error log. If an error was recorded, see Chapter 6, “Symptom-to-FRU index,” on page 77.

9.Start the diagnostic programs.

10.Check for the following responses:

vOne beep

vReadable instructions or the main menu

002 DID YOU RECEIVE BOTH OF THE CORRECT RESPONSES?

NO. Find the failure symptom in Chapter 6, “Symptom-to-FRU index,” on page 77.

YES. Run the diagnostic programs. If necessary, see “Diagnostic programs and error messages” on page 25.

If you receive an error, see Chapter 6, “Symptom-to-FRU index,” on page 77.

If the diagnostic programs were completed successfully and you still suspect a problem, see “Undetermined problems” on page 101.

Diagnostic tools overview

The following tools are available to help you diagnose and solve hardware-related problems:

vBeep codes and error messages

The beep codes indicate that the power-on self-test (POST) or the baseboard management controller (BMC) have detected a problem during startup. Error messages also appear during startup if POST detects a hardware-configuration problem. See “Beep codes” on page 77 for more information.

vDiagnostic programs and error messages

Real Time Diagnostics tests the major components of the BladeCenter unit, including the managemente modules, switch modules, CD-ROM drive, diskette drive, and the blade server, while the server operating system is running. Real Time Diagnostics can either be plugged into an existing IBM Director environment or installed without IBM Director present. For documentation and download information for the Real Time Diagnostics, go to http://www.ibm.com/servers/xseries/systems_management/xseries_sm.html.

Notes:

1.As of the date of this document, the IBM Director CD does not come with the

BladeCenter T unit. If you have the BladeCenter T unit, see the IBM

Eserver BladeCenter HS40 Type 8839 Installation and User’s Guide for more information.

22BladeCenter HS40 Type 8839: Hardware Maintenance Manual and Troubleshooting Guide