SERVICE
WARNING – Disconnect the dispenser from the power source before the removal of any panel or the replacement of any component. WARNING - Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel. Disconnect the dispenser fromthe power source when servicing, except when electrical tests are required and the test procedure specifically states to connect the dispenser to the power source.
Component Access - |
P1770.30 |
The check valve, electronic control assembly, safety overflow switch, solenoid valve, overflow tube tempera- ture sensor and terminal block are located at the rear of the dispenser. Access is gained by removing the upper and lower rear panels. The upper is attached with six
Component Access - H10X
:$51,1* |
9HU\+RW:DWHU |
8VH:LWK&DUH |
P878.30 |
The check valve, electronic control assembly, over- flow protection switch, solenoid valve, overflow tube temperature sensor, triac assembly (EARLY MODELS ONLY) and terminal block are located on the side of the dispenser. Access is gained by removing the side panel. The panel is attached with eight
Faceplate Removal - H5 ELEMENT: After removing top cover, remove the two upper screws securing the faceplate. Carefully lift faceplate straight up until the three lower screws clear the key holes.
7 | 42311 022311 |
|