Bunn DV, H5X Problem, Probable Cause, Remedy, TROUBLESHOOTING cont, Water strainer/flow control

Models: DV H5E H5X

1 24
Download 24 pages 29.7 Kb
Page 5
Image 5

TROUBLESHOOTING (cont.)

 

 

Problem

Probable Cause

Equipment will not operate

2.

Safety overflow switch

(cont.)

 

 

Automatic refill will not oper-

1.

No water

ate after drawing hot water.

2.

Water strainer/flow control

 

3. Liquid level system

4. Solenoid valve

Water flows into the tank con-

1.

Solenoid valve

tinuously (Dispenser discon-

 

 

nected from power source).

 

 

Water flows into the tank con-

1.

Liquid level system

tinuously (Dispenser connect-

 

 

ed to power source).

 

 

Water is cold.

1.

Safety overflow switch

 

2.

Limit thermostat

Remedy

Refer to Service – safety overflow switch for testing procedures.

Check plumbing and shut-off valves.

(A)Direction of flow arrow must be point- ing towards dispenser.

(B)Remove the strainer/flow control and check for obstructions. Clear or replace.

Refer to Service – electronic controls for testing procedures.

Refer to Service – solenoid valve for test- ing procedures.

Refer to Service – solenoid valve for test- ing procedures.

Refer to Service – electronic controls for testing procedures.

Refer to Service – safety overflow switch for testing procedures.

Refer to Service – limit thermostat for testing procedures.

CAUTION – Do not eliminate or bypass limit thermostat. Use only B.O.M. replacement part #23717.0003.

3.

Tank heater

Refer to Service – tank heater for testing

 

 

procedures.

4.

Temperature control

Refer to Service – electronic controls for

 

 

testing procedures.

5

42311 071310

 

Page 5
Image 5
Bunn DV, H5X, H5E Problem, Probable Cause, Remedy, TROUBLESHOOTING cont, Water strainer/flow control, Safety overflow switch