TROUBLESHOOTING (cont.) |
|
|
Problem | Probable Cause | |
Equipment will not operate | 2. | Safety overflow switch |
(cont.) |
|
|
Automatic refill will not oper- | 1. | No water |
ate after drawing hot water. | 2. | Water strainer/flow control |
|
3. Liquid level system
4. Solenoid valve
Water flows into the tank con- | 1. | Solenoid valve |
tinuously (Dispenser discon- |
|
|
nected from power source). |
|
|
Water flows into the tank con- | 1. | Liquid level system |
tinuously (Dispenser connect- |
|
|
ed to power source). |
|
|
Water is cold. | 1. | Safety overflow switch |
| 2. | Limit thermostat |
Remedy
Refer to Service – safety overflow switch for testing procedures.
Check plumbing and
(A)Direction of flow arrow must be point- ing towards dispenser.
(B)Remove the strainer/flow control and check for obstructions. Clear or replace.
Refer to Service – electronic controls for testing procedures.
Refer to Service – solenoid valve for test- ing procedures.
Refer to Service – solenoid valve for test- ing procedures.
Refer to Service – electronic controls for testing procedures.
Refer to Service – safety overflow switch for testing procedures.
Refer to Service – limit thermostat for testing procedures.
CAUTION – Do not eliminate or bypass limit thermostat. Use only B.O.M. replacement part #23717.0003.
3. | Tank heater | Refer to Service – tank heater for testing |
|
| procedures. |
4. | Temperature control | Refer to Service – electronic controls for |
|
| testing procedures. |
5 | 42311 071310 |
|