Bunn H5X, H5E, DV manual Problem, Probable Cause, Remedy, Inspect the tank assembliy for excess lime

Models: DV H5E H5X

1 24
Download 24 pages 29.7 Kb
Page 6
Image 6

TROUBLESHOOTING (cont.)

 

 

 

Problem

Probable Cause

Remedy

Water boils continuously.

1.

Temperature control

Refer to Service – electronic controls for

 

 

 

testing procedures.

 

2.

Lime build-up

Inspect the tank assembliy for excess lime

 

 

 

deposits. Delime as required.

CAUTION – Tanks and tank components should be delimed reglarly depending on local water conditions. Exces- sive mineral build-up on stainless steel surfaces can initiate corrosive reactions resulting in serious leaks.

Dispenser is making unusual 1.

Plumbing lines

noises.

 

3.

Water supply

Ready indicator will not light.

1. Temperature control

Plumbing lines should not be resting on the counter top.

(A)The dispenser must be connected to a cold water line.

(B)Water pressure to the dispenser must not be higher than 90 psi (620 kPa). Install a regulator if necessary to lower the work- ing pressure to approximately 50 psi (345 kPa).

Refer to Service – electronic controls for testing procedures.

2. Ready Indicator LED

Replace the indicator LED.

6

42311 071310

 

Page 6
Image 6
Bunn H5X Problem, Probable Cause, Remedy, Inspect the tank assembliy for excess lime, Plumbing lines, Temperature control