SERVICE (cont.)
Tank Heater
Location:
The tank heater is located in the tank lid.
H 5 |
P4093 |
FIG. 16a TANK HEATER |
H 10 |
P1993 |
FIG. 16b TANK HEATER |
Test Procedure:
1.Disconnect the dispenser from the power source.
2.Check the voltage across the terminals of the tank heater with a voltmeter. Connect the dispenser to the power source. The indication must be:
a.) 100 to 120 volts ac for 100 to 120 volt models or
b.) 200 to 240 volts ac for 200 to 240 volt models or
c.) 230 volts ac for 230 volt models.
3.Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, replace the tank heater.
4.Remove the tank heater from the tank lid and in- spect it for cracks in the sheath.
If the sheath shows no sign of damage, proceed to #5. If the sheath is damaged, replace the tank heater.
5.Check for continuity across the tank heater termi- nals.
If continuity is present as described, reinstall the tank heater. The tank heater is operating properly.
If continuity is not present as described, replace the tank heater.
Removal and Replacement:
1.Remove the wires to the tank heater.
2.Remove the
3.Remove the tank heater.
4.Inspect the tank heater gasket and replace if neces- sary.
5.Securely install the new tank heater. Be certain of a watertight seal.
6.Reconnect the wires, FIG. 10.
BLU to Control | BLK to Limit |
Board Relay | Thermostat |
P1780
FIG. 16c TANK HEATER WIRING
HEATER | RESISTANCE | |
07.44 | - 08.67 | |
13.43 | - 15.51 | |
10.09 | - 11.99 | |
08.85 | - 10.23 | |
06.67 | - 07.70 |
TERMINAL TO SHEATH - INFINITE (OPEN)
16 | 42311 071310 |
|