Manual background

Note: See Chapter 7, “Parts listing, Type 8839,” on page 105 to determine which components should be replaced by a field service technician.

Error code/symptom

FRU/action

 

 

167-400-001 ISMP: Failed

I/O board

(ISMP failed to communicate with I/O

 

 

board.)

 

 

 

 

 

167-400-002 ISMP: Failed

1.

Processor board

(ISMP failed to communicate with processor

2.

I/O board

board.)

 

 

167-400-003 ISMP: Failed

1.

Processor board

(ISMP failed to communicate with

2.

I/O board

processors.)

3.

Microprocessor

 

 

 

 

167-400-004 ISMP: Failed

1.

Processor board

(ISMP failed to communicate with DIMMs.)

2.

I/O board

 

 

3.

DIMMs

 

 

 

180-XXX-001

1.

Front panel

(Failed front LED panel test.)

2.

I/O board

 

 

 

180-XXX-000(Diagnostics LED failure)

Run diagnostics panel LED test for the failing LED.

 

 

 

180-XXX-001

1. Front bezel with customer interface card

(Failed front LED panel test)

2.

System board

 

 

 

180-XXX-002

System board

(Failed diagnostics LED panel test)

 

 

 

 

180-XXX-003

System board

(Failed system board LED test)

 

 

 

 

 

180-XXX-005

1. SCSI storage expansion unit

(Failed SCSI backplane LED test)

2.

System board

 

 

 

 

201-XXX-0nn

1. Replace DIMM nn, where nn is the DIMM number.

(Failed memory test.)

2.

System board.

 

 

 

 

201-XXX-Y99

1. Isolate the failing DIMM.

(Multiple DIMM failure, see error text)

 

a. Replace a DIMM in bank with a known good DIMM.

 

 

 

 

b. Rerun memory diagnostic for the failing bank.

 

 

c. If test fails, mark replaced DIMM as good DIMM.

 

 

d. If test passes, mark replaced DIMM as bad DIMM.

 

 

e. If DIMM tested is bad, replace the bad DIMM.

 

 

f. If DIMM tested is good, do not replace it.

 

2. Repeat steps 1a through 1f with other DIMMs in the failing bank

 

 

until the error is corrected.

 

3. If error is not corrected, replace system board.

 

 

 

202-XXX-001

1.

Microprocessor 1

(Failed system cache test)

2.

System board

 

 

 

 

202-XXX-002

1.

Microprocessor 2

(Failed system cache test)

2.

System board

 

 

 

 

202-XXX-003

1.

Microprocessor 3

(Failed system cache test)

2.

System board

 

 

 

 

Chapter 6. Symptom-to-FRU index 85

Page 95
Image 95
IBM HS40 manual Error code/symptom