POST error codes

POST error codes

The following table lists error codes that might be sent to the management module for error logging as BMC pass-through error entries for the management module system-error log (SEL).

Note: The syntax of error logging between the management module and the SEL might be different. Local SEL error codes might differ from the SEL entries logged by the management module for identical event types.

In the following error codes, X can be any number or letter.

Note: See Chapter 7, “Parts listing, Type 8839,” on page 105 to determine which components should be replaced by a field service technician.

Error code/symptom

FRU/action

 

 

 

0000

1.

Run diagnostics.

(Timer error)

2.

Battery.

 

 

3.

I/O board.

 

 

0005

Information only; no action required.

(CMOS checksum bad loading defaults)

 

 

 

 

0012

Run the Configuration/Setup Utility program, and set the date and

(CMOS date/time not set)

time.

 

 

 

0040

1.

I/O board

(Refresh timer test failed)

2.

Processor board

 

 

 

0044

I/O board

(DMA controller error)

 

 

 

 

0045

I/O board

(DMA-1 error)

 

 

 

 

0046

I/O board

(DMA-2 error)

 

 

 

 

004C

I/O board

(Keyboard/interface error)

 

 

 

 

 

004D

1.

Reset primary hard disk.

(Primary master hard disk error)

2.

Run diagnostics.

 

 

3.

Primary hard disk.

 

4.

I/O board.

 

 

 

004F

1.

Reset secondary hard disk.

(Secondary master hard disk error)

2.

Run diagnostics.

 

 

3.

Secondary hard disk.

 

4.

I/O board.

 

 

0055

Primary master hard disk drive

(Primary master drive - ATAPI

 

 

incompatible)

 

 

 

 

0057

Secondary master hard disk drive

(Secondary master drive - ATAPI

 

 

incompatible)

 

 

 

 

005D

ATA drive

(ATA SMART failure error (dynamic string))

 

 

 

 

 

Chapter 6. Symptom-to-FRU index 79

Page 89
Image 89