IBM HS40 manual Hardware Maintenance Manual and Troubleshooting Guide, Documentation CD

Models: HS40

1 172
Download 172 pages 19.46 Kb
Page 102
Image 102
8677 Hardware Maintenance Manual and Troubleshooting Guide).

Note: See Chapter 7, “Parts listing, Type 8839,” on page 105 to determine which components should be replaced by a field service technician.

Monitor problems

Symptom

FRU/action

 

 

Testing the monitor.

See the information that comes with the monitor for adjusting and testing

 

instructions. (Some IBM monitors have their own self-tests.)

 

 

The screen is blank.

1. Make sure that:

 

 

v The keyboard/mouse/video select button LED on the front of the blade

 

server is lit, indicating that the blade server is connected to the shared

 

BladeCenter monitor.

 

v The system power cord is plugged into the BladeCenter power module and a

 

working electrical outlet.

 

v The monitor cables are connected properly.

 

v The monitor is turned on and the Brightness and Contrast controls are

 

adjusted correctly.

 

v If the computers are C2T chained together, verify that:

 

– The C2T chain cables are securely connected to the computers.

 

– The C2T breakout cable is connected properly.

 

– A computer that is turned on is selected.

 

Important: In some memory configurations, the 3-3-3 beep code might sound

 

during POST followed by a blank display screen. If this occurs and the Boot

 

Fail Count feature in the Start Options of the Configuration/Setup Utility

 

program is set to Enabled (its default setting), you must restart the computer

 

three times to force the system BIOS to reset the CMOS values to the default

 

configuration (memory connector or bank of connectors enabled).

 

2. If you have verified these items and the screen remains blank, replace:

 

a. Monitor

 

b. Management module on the BladeCenter (see the IBM BladeCenter Type

 

8677 Hardware Maintenance Manual and Troubleshooting Guide).

 

 

Only the cursor appears.

Make sure that the keyboard, video and mouse on the BladeCenter have not

 

been switched to another blade server. If the problem remains,

 

see“Undetermined problems” on page 101.

 

 

The monitor goes blank when

Make sure that the monitor cable is connected to the video port on the

you direct it to a working

BladeCenter management module. Some IBM monitors have their own self-tests.

blade server, or goes blank

If you suspect a problem with your monitor, see the information that comes with the

when you start some

monitor for adjusting and testing instructions.

application programs in the

If you still cannot find the problem, try using the monitor with another blade server.

blade servers.

 

If the problem persists, see the IBM BladeCenter Type 8677 Hardware

 

Maintenance Manual and Troubleshooting Guide on the IBM BladeCenter

 

Documentation CD.

 

 

92BladeCenter HS40 Type 8839: Hardware Maintenance Manual and Troubleshooting Guide