North Star MHOTPWR specifications Troubleshooting Guide, Pressure Washer Will Not Run - No Power

Models: MHOTPWR

1 27
Download 27 pages 11.42 Kb
Page 18
Image 18
Troubleshooting Guide

 

 

Troubleshooting Guide

 

 

 

 

 

Pressure Washer Will Not Run - No Power

 

Causes

 

 

Solutions

 

Machine not plugged in

 

 

Plug machine in

 

GFCI tripped

 

 

Make sure machine is dry. Press RESET on the GFCI

 

Machine turned OFF

 

 

Turn Pump switch ON

 

Line circuit breaker tripped

 

 

Check for tripped circuit breaker in building

 

 

 

 

 

Circuit Breaker Trips During Operation

 

Causes

 

 

Solutions

 

Voltage too low

 

 

Check the voltage

 

Circuit Breaker Overloaded

 

 

Make sure to use NEMA specified receptacle. Make sure there is no other

 

 

 

 

equipment using the same circuit. - see Specifications

 

Pressure set too high

 

 

Check/adjust pressure setting on unloader.

 

 

 

Pressure Washer Runs But No Pressure

 

Causes

 

 

Solutions

 

Partially clogged or damaged nozzle

 

 

Clean or replace nozzle

 

Low water flow

 

 

Make sure the water supply is more than 4 gpm

 

 

 

Pressure Washer Surges Or Cycles While In Bypass

 

Causes

 

 

Solutions

 

Leak between unloader and gun.

 

 

Check all connections between unloader and gun for leaks. Tighten loose

 

 

 

 

components and replace damaged components.

 

Gun leaking internally

 

 

Replace spray gun

 

 

 

 

 

Smoke From Heat Exchanger

 

Causes

 

 

Solutions

 

Air band not adjusted properly

due to

Adjust the air band until the burner burns cleanly. See Oil Burner under

 

different elevation

 

 

Installation Instructions

 

Poor quality fuel

 

 

Use Kerosene for the cleanest burn

 

 

 

 

 

Water Not Heating Sufficiently

 

Causes

 

 

Solutions

 

Scale build-up in coil

 

 

See Coil Descaling under Maintenance Instructions

 

Coil is full of soot

 

 

See Coil Desooting under Maintenance Instructions

 

 

 

 

 

Safety Relief Valve Sprays Water

 

Causes

 

 

Solutions

 

Unloader/Burner Control Problem

 

 

Call customer service

 

 

 

 

 

Poor Or No Detergent Supply

 

Causes

 

 

Solutions

 

Soap control knob set too low.

 

 

Adjust soap control knob

 

Inadequate detergent supply

 

 

Refill detergent container. Make sure the chemical strainer is fully

 

 

 

 

submerged

 

High pressure hose too long

 

 

Use less hose. Move machine closer to the work.

 

Chemical strainer or injector clogged

 

 

Clean the strainer and injector. Always start with a clean detergent

 

 

 

 

container. Run clean water through the injector after each use.

18

Page 18
Image 18
North Star MHOTPWR Troubleshooting Guide, Pressure Washer Will Not Run - No Power, Circuit Breaker Trips During Operation