7. TROUBLE SHOOTING
7-1.BEFORE SVC CHECKING
■Be careful of electric shock or disconnecting the parts while trouble shooting.
■Voltage of each terminal in
7-2.QC TEST MODE.
①Pressing Rinse, and Spin button simultaneously.
②Press the Power button, while the above condition.
③ Press the Start/Pause button as follows.
Number of times the | Check Point | Display Status | |
Start/Pause button is pressed | |||
|
| ||
None | Turns on all lamps and locks the door. |
| |
|
|
| |
1 time | Tumble clockwise. | rpm (40~50) | |
|
|
| |
2 times | Low speed Spin. | rpm (600~650) | |
|
|
| |
3 times | High speed Spin. | rpm (1300~1350) | |
|
|
| |
4 times | Inlet valve for prewash turns on. | Water level frequency (25~65) | |
|
|
| |
5 times | Inlet valve for main wash turns on. | Water level frequency (25~65) | |
|
|
| |
6 times | Inlet valve for hot water turns on. | Water level frequency (25~65) | |
|
|
| |
7 times | Inlet valve for dry water turns on. | Water level frequency (25~65) | |
|
|
| |
8 times | Tumble counterclockwise. | rpm (40~50) | |
|
|
| |
9 times | Heater turns on for 3 sec. | Water temperature | |
|
|
| |
10 times | Circulation pump turns on. | Water level frequency (25~65) | |
|
|
| |
11 times | Drain pump turns on. | Water level frequency (25~65) | |
|
|
| |
12 times | Power off and unlock the door. | Turn off all lamps. | |
|
|
|
7-3.HOW TO KNOW THE WATER LEVEL FREQUENCY
✽Press the Rinse and Spin button simultaneously.
The digits means water level
ex) 241 : Water level frequency = 241×
■Thermistor in tub : Press the [Temp.] button.
■Thermistor in dry duct : Press the [Dry] button.
■Thermistor in condensing duct : Press the [Intensive] and [Spin] button simultaneously.