Equator MJ9200D installation manual Getting things ready to install your appliance, Electricity

Page 5

Installing/Removing

Getting things ready to install your appliance (continued)

Electricity

Make sure that the voltage and frequency available correspond with the values stated on the data plate located at the back of the machine and that the electric system is dimensioned to withstand the maximum current shown on the data plate. If the socket the machine is connected to does not correspond with the plug, replace the plug with a suitable one and avoid using adapters or shunts since they could cause over heating and burn out.

Grounding

This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having and equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING- Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified or service representative or personnel if you are in doubt as to whether the appliance is properly grounded.

Do not modify the plug provided with the appliance: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

Electrical Specifications:

Voltage/Amperage - 115V, 12 Amp, 60 Hz 3 Prong plug attached to the appliance in the factory Circuit/Protection - 3 wires single phase, 120V, 60 Hz, AC separate 15 amp circuit or greater.

Recessed, Closet and Alcove Installations

This appliance may be installed in a recessed area, closet or alcove. All measurements are in inches.

If the appliance is to be installed in a closet with zero clearance on the side of the appliance, a total of 12 square inches of free air space movement to the back of the unit must be allowed into the closet.

If a door is to be installed that potentially encloses the unit while running, the door must allow for a minimum of 20 square inches of free air movement. There must also be a 1” space from the front of the unit to the closed door and 1” from the back of the unit to the wall. Additional spacing should be considered for easy installation, servicing, removal and compliance with applicable local, state and federal codes.

The floor must be able to support at least 280 lbs and a surface that is solid and level. If machine is to be placed in cabinet, up off the floor, it may be necessry to secure the drun with a tether to prevent excessive drum movement. Plese call Majestic Appliances for more information.

Installations in RV’s or Marine pleasure craft suggest that the machine might best be installed midships in the boat, or over the axles of the RV where movement is at a minimum.

Adequate blocking should prevent extreme movement when installed in an RV or Marine pleasure craft.

If the appliance is to be installed in a closet, the installation must be completed by a quali≠fied person or service representative. Additional clearances for floor, wall or door moldings may be required.

Page 3

Image 5
Contents Model MJ-9200D Vented Dryer Installation ManualWelcome Unpacking Getting things ready to install your applianceInspecting When to Remove Shipping Bolts Electricity Getting things ready to install your applianceRecessed, Closet and Alcove Installations Correct Leveling of Unit is Essential Exhaust Duct Installation