| Care and cleaning | 27 |
|
|
|
|
|
|
|
|
|
7. When no more water comes out, un- screw the pump cover by turning it an-
Clean the filter under a tap, to remove any traces of fluff.
8. Remove foreign bodies and fluff from the filter seat and from the pump im- peller.
9.Check carefully whether the pump im-
peller rotates (it rotates jerkily). If it doesn’t rotate, please contact your Serv- ice Centre.
10. Put the cap back on the emergency emptying hose and place the latter back in its seat.
11. Replace the filter into the pump by in- serting it correctly into the special guides. Screw the pump cover firmly by turning it clockwise.
12. Refit the flap and close the pump door.
WARNING!
When the appliance is in use and depending on the programme selected there can be hot water in the pump.
Never remove the pump cover during a wash cycle, always wait until the appliance has fin- ished the cycle, and is empty. When refitting the pump cover, ensure it is securely