GAS REQUIREMENTS
Use only Natural or LP (liquid propane) gases.
THE INSTALLATIONMUSTCONFORM WITH LOCAL CODES, OR IN THEABSENCE OF LOCALCODES, WITH THE NATIONALFUELGAS CODEANSI/Z223.1, LATESTREVISION (FOR THE UNITEDSTATES), OR WITH THE
A gas dryer is equipped with a burner orifice for operation on NATURALgas. If the dryer is to be operated on LP gas, it must be converted for safe and proper performanceand must be converted by a qualified service technician. Conversion kits from NATURALto LP,or LP to NATURALare available through your local dealer (see Accessories). If other conversionsare required, check with the local gas utility for specific informationconcerningconversion requirements.
Each dryer will provide an input of 22,000 B.T.U.per hour.
A1/2 inch gas supply line is recommendedand must be reducedto connectto the 3/8 inch gas line on the dryer.
The internal gas
The National Fuel Gas Code requiresthat an accessible, approvedmanual gas shut off valve be installed within 6 feet of the dryer.
Additionally,a 1/8 inch N.P.T.(NationalPipe Thread) pluggedtapping, accessiblefor test gauge connection, must be installed immediatelyupstream of the gas supply connectionto the dryer.
The dryer mustbe disconnectedfrom the gas supply pipingsystemduringanypressuretestingof thesystem.
DO NOT
NOTE: As a courtesy, most local gas utilities will inspect a gas appliance installation.
GAS IGNITION -
The dryer use an automaticignitionsystemto ignitethe burner. There is no constant burning pilot.
GROUNDING
•Improperconnectionof the
•Do not modify the plug provided with the appliance- if it will not fit the outlet, have a properoutletinstalledby a qualifiedelectrician.
•Toprevent unnecessary risk of fire, electrical shock or personal injury, all wiring and groundingmust be done in accordancewith the National Electrical Code
ANSI/NFPA,No.
I 1_0I doubt as to whether the applianceis properlygrounded.
CSA
•All gas installations must be done in accordancewith the National Fuel Gas Code