Electrical System Requirements
Because of potentially inconsistent voltage capabilities, the use of this dryer with power created by gas powered gen- erators, solar powered generators, wind powered generators or any other generator other than the local utility company is not recommended.
Electrical requirements for electric dryer
CIRCUIT - Individual 30 amp. branch circuit fused with 30 amp. time delay fuses or circuit breakers. Use separately fused circuits for washer and dryer. DO NOT operate a washer and a dryer on the same circuit.
POWER SUPPLY -
This dryer is internally grounded to neutral unless it was manufactured for sale in Canada. Grounding through the neutral link is prohibited for: (1) new branch circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes do not permit grounding through the neutral.
OUTLET RECEPTACLE - NEMA
GROUNDING CONNECTION - See “Grounding requirements” in Electrical Installation section.
3-wire receptacle
(NEMA type 10-30R)
The dryer MUST employ a
4-wire receptacle
(NEMA type 14-30R)
The dryer MUST employ a
Dryers manufactured for sale in Canada have factory- installed,
Electrical requirements for gas dryer
CIRCUIT - Individual, properly polarized and grounded 15 amp. branch circuit fused with 15 amp. time delay fuse or circuit breaker.
POWER SUPPLY -
POWER SUPPLY CORD - The dryer is equipped with a 120 volt
GROUNDING CONNECTION - See “Grounding requirements” in Electrical Installation section.
Grounding type wall receptacle
Do not, under
any circumstances, cut, remove,
or bypass the grounding prong.
Power cord with