Installing the dryer (cont.).
| Remove the screws securing the terminal block | |
1 | ||
access cover and the strain relief mounting | ||
| ||
| bracket located on the back of the dryer upper | |
| corner. | |
| Install a | |
2 | ||
cord entry hole of the mounting bracket. Use | ||
| ||
| a strain relief which attaches to the mounting | |
| bracket with a nut. | |
| at this time. | |
| Thread a | |
3 | ||
minimum copper conductor power cord through | ||
|
the strain relief.
4
5
6
Attach the power cord neutral (center wire) conductor to the
Attach the remaining two power cord outer conductors to the outer
WARNING: Do not make a sharp bend or crimp wiring/conductor at connections.
Reattach the strain relief mounting bracket to the back of the dryer with one screw. Tighten
Green ground screw
Silver terminal
7
screw securely.
Tighten the screws securing the cord restraint firmly against the power cord.
Green neutral |
|
ground wire | Nut |
Tighten nut to these threads
Use copper | Power cord |
Strain relief | |
conductors only. | mounting bracket |
8
9
Tighten the strain relief nut securely so that the strain relief does not turn.
Reinstall the terminal block access cover.
Safety Instructions
Care and Cleaning
Installation Instructions
Customer Service
| Remove the screws securing the terminal block | |
1 | ||
access cover and the strain relief mounting | ||
| ||
| bracket located on the back of the dryer upper | |
| corner. | |
| Install a | |
2 | ||
hole of the mounting bracket. Use a strain relief | ||
| ||
| which attaches to the mounting bracket with a | |
| nut. | |
| Remove the green neutral ground wire from the | |
3 | ||
green ground screw located above the terminal | ||
|
block.
Typical 4 |
|
|
|
| Black 240V |
conductor |
|
|
| Typical | White neutral |
receptacle |
|
|
| 4 conductor cord | |
|
|
|
|
Red 240V
Green ground
4 Thread a
5 Attach the green power cord ground wire to the cabinet with the green ground screw.
|
| Attach the white (neutral) power cord |
| 6 | |
| conductor from the power cord and the green | |
|
| |
|
| ground wire from the dryer harness to the silver- |
14 |
| colored center terminal on the terminal block. |
| Tighten the screw securely. |
7 Attach the red and black power cord conductors to the outer
Green ground | Green power cord ground wire | ||
Silver terminal | |||
screw |
|
Green neutral |
|
| Terminal block | ||||
|
| ||||||
| Black |
| |||||
ground wire |
|
|
| ||||
|
|
|
| ||||
| Red | White Nut | Tighten nut to | ||||
|
|
|
| ||||
|
|
|
| these threads | |||
|
|
|
|
|
|
| |
|
|
|
| Strain |
| ||
|
|
|
| relief |
| ||
| Power cord |
| mounting |
| |||
|
|
|
|
| |||
|
|
|
| bracket |
|
WARNING: Do not make a sharp bend or crimp wiring/conductor at the connections.
8 Tighten the screws securing the cord restraint firmly against the power cord.
9 Tighten the strain relief nut securely so the strain relief does not turn.