Airstream PNEG-339 service manual Quick Reference Guide, Electronic Monitoring Control System

Page 51

QUICK REFERENCE GUIDE

ELECTRONIC MONITORING CONTROL SYSTEM

Important! To activate the controller after turning on the control power, press the reset button.

To set the dry, cool, unload and out of grain timers:

Press the dry, cool, unload or out of grain button

Press the modify button

Press the increase or decrease button to get desired setting

Press the enter button when desired setting is reached

To set the load and unload delays:

Press the load or unload button

Press the modify button

Press increase or decrease button to get desired setting

Press the enter button when desired setting is reached

Pressing the increase and decrease buttons simultaneously will access the following programming features:

Safety circuit shutdown log

Dryer model number

Fan delay

BPH factor

Fill auger options:

a.Center fill auger

b.End fill auger

Metering roll monitor disabling feature

Air switch disabling feature

These features are accessed se- quentially as listed above. Press the

increase or decrease buttons to change a setting. Press the enter button to move from feature to fea- ture.

Pressing and holding the reset but- ton for five seconds will access the following programming features:

Calendar year setting

Calendar month setting

Calendar day setting

Clock hour setting

Clock minute setting

Bushel counter reset

Batch counter reset

These features are accessed sequen- tially as listed above. Press the in- crease or decrease buttons to change a setting. Press the enter but-

ton to move from feature to feature. To change the marquee on the

LCD display:

Press and hold the modify button whileturningonthecontrol power

Press the increase or decrease button to change a character

Press the unload button to move the cursor to the right

Press the dry button to move the cursor to the left

Press the cool button to delete a character

Press enter when the desired marquee is displayed

To reset the computer to the original default setting, turn off the computer, press and hold the green AUX 1 but- ton and turn on the computer. NOVRAM will appear on the LCD dis- play. The year, date, time and min- utes may be changed now, and the shutdown history may also be cleared.

Note: If the history is cleared the dryer model number must be reset or only the bottom fan will operate (if so equipped).

Dryer owner and Airstream associates check the Electronic Monitoring Control System.

51

Image 51
Contents Ryer Operation Page Table of Contents Series Dryer Operation and ServiceWarranty Dryer Operation Roof WARNING, Operation & SafetySafety Alert Symbol Roof Damage Warning and DisclaimerSafety Alert Decals Safety Precautions Moisture Control Switch Dryer Control PanelMoisture Control Thermostat FAN Switch Control Power SwitchDrying Mode Switch Load Auger SwitchDryer Power Start Switch Dryer Power Stop SwitchLOW Speed Metering Roll Potentiometer Setting the DRY 16, Cool 17 and Unload 18 Batch Timers Setting the OUT Grain TimerElectronic Monitoring Control System Setting the Load 20 and Unload 21 Delays Dryer Safety CircuitUtilizing Bushel Counter Safety Circuit Shutdown Messages PRE Season Inspection Dryer PRE Start ChecksLoad Auger ONE Speed OperationMetering Roll Operation Burner Test Fire Burner SafetyStaged Batch Check Dryer ShutdownEmergency Continuous Flow and Continuous Batch Start UP Procedure Dryer Start UPContinuous Flow Operation Staged Batch Operation Dry cycle FAN & Heater Switch SettingsFull Heat Dry & Cool Series Batch Timer SettingsQuick Start UP Procedure Full Start UP CheckFilling the Dryer Starting the Dryer Adjusting the TemperatureFull HEAT-CONTINUOUS Flow Operation Full Heat Series Continuous Flow Metering Roll SettingsAdjusting the Moisture Control Quick Start UP Procedure Series Service Guide Service Seasonal Inspection and ServiceLube Procedures Leaks. See page 16 for burner Suggested LubricantsFAN Propellor Removal and Installation Threaded Bushing HolesClearance Holes FAN Motor Removal and Installation Heater Parts Removal and Installation Main Controls Metering Roll ServicingHOW to Determine a Metering Roll Problem HOW to Clear a Jammed Metering RollService Tool Page Page Page Page Page Page Page Page Page Page Trouble Analysis Procedure An over temperature condition has occurred inside the left Service Service Service Quick Reference Guide Page Page 1004 E. Illinois St., Box Assumption, IL Phone Fax November

PNEG-339 specifications

The Airstream PNEG-339 is a highly regarded model in the realm of agricultural storage and handling equipment, specifically designed for grain management. Its innovative features and robust technologies make it a valuable asset for farmers and grain handlers seeking efficiency and reliability.

One of the primary characteristics of the PNEG-339 is its seamless construction. Built with high-quality materials, the unit is engineered to withstand the rigors of outdoor environments while providing durable protection for stored grains. The design minimizes maintenance requirements, ensuring that users can focus on their core agricultural operations without the distraction of frequent repairs.

The PNEG-339 is equipped with advanced aeration systems that enhance the preservation of grain quality. This technology allows for optimal airflow circulation, reducing moisture levels and minimizing the risk of spoilage. By maintaining the ideal conditions for grain storage, farmers can ensure better yields and profitability.

Another notable feature of the PNEG-339 is its scalability. This model can easily be integrated into existing grain handling systems, accommodating various storage capacities. Whether managing small-scale operations or large agricultural enterprises, the PNEG-339 offers flexibility in design and implementation, making it suitable for diverse agricultural needs.

The unit also boasts user-friendly controls and monitoring systems, allowing operators to manage grain conditions efficiently. Real-time data and automated alerts assist in maintaining optimal storage conditions, thus reducing labor costs and enhancing operational efficiency. As a result, farmers can make informed decisions quickly and effectively.

Additionally, the PNEG-339 incorporates energy-efficient technologies that contribute to sustainability in agriculture. By utilizing energy-saving components, this model not only lowers operational costs but also aligns with the growing emphasis on environmentally responsible farming practices.

Overall, the Airstream PNEG-339 stands out as a top-tier choice for grain storage and handling. With its durable construction, advanced aeration systems, scalability, user-friendly controls, and energy efficiency, it meets the demands of modern agricultural operations. Its design and functionality reflect a commitment to quality and performance, making it an essential tool for those in the agricultural sector aiming to enhance their productivity and maintain the integrity of their grain stores.