AEG T37400 operating instructions Permanent connection, Blue- Neutral Brown- Live

Page 25

Blue- Neutral

Brown- Live

GREEN & YELLOW

E

 

13 A

N

L

 

BROWN

BLUE

P1041

CORD CLAMP

 

The wire coloured green and yellow must be connected to the termi- nal marked with the letter «E» or by the earth symbol or coloured green and yellow.

The wire coloured blue must be connected to the terminal «N» or coloured black.

The wire coloured brown must be connected to the terminal marked «L» or coloured red.

Upon completion there must be no cut, or stray strands of wire pre- sent and the cord clamp must be secure over the outer sheath.

Warning! A cut off plug inserted into a 13 amp socket is a serious safe- ty (shock) hazard.

Ensure that the cut off plug is disposed of safely.

Permanent connection

In the case of permanent connection it is necessary that you install a double pole switch between the appliance and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current electrical regulations.

The switch must not break the yellow and green earth cable at any point.

25

Image 25
Contents Lavatherm T37400 Dear customer Contents Technical specifications General safety Safety instructionsPositioning and connection Child safetyGeneral instructions For safety reasons, the appliance must not be modifiedProper use Packaging materials DiscardingSpinning Tips for environmental protectionDryness Minutes Select the correct drying programmeFront view Structure of the applianceRear view This button must also be pressed after a power cut Low temperature buttonControl panel Buzzer OFF buttonLights Brief operating instructions Before the first drying cycleSort out the laundry DryingOpen the door Load the laundrySelect the drying programme/time Switch the machine onSelect the required options Start the machineSwitch the tumble dryer off Anti-creasing phaseClean the filters Remove or add laundryProgramme charts Brief summary of fabric information Care symbolsExternal cleaning Cleaning and careCleaning the door Cleaning the filtersCleaning the panel and the controls Cleaning the drum Smoething not working? Something not working?Long time Use Domestic Permissible ambient temperature Technical specificationsElectrical connection Blue- Neutral Brown- Live Permanent connectionEnsure that the cut off plug is disposed of safely Door reversal Special accessoryKit Washing/drying column This is a chargeable optionService