American Dryer Corporation products embody advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble free operation.

ONLY qualified technicians should service this equipment.

OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation manual included with the dryer.

The following “FOR YOUR SAFETY” caution must be posted near the dryer in a prominent location.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

POUR VOTRE SÉCURITÉ

Ne pas entreposer ni utiliser d’essence ni d’autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil.

We have tried to make this manual as complete as possible and hope you will find it useful. ADC reserves the right to make changes from time to time, without notice or obligation, in prices, specifications, colors, and material, and to change or discontinue models.

Important

For your convenience, log the following information:

DATE OF PURCHASE

_________________________________________________ MODEL NO. _________________

RESELLER’S NAME

_________________________________________________________________________________

Serial Number(s) ____________________________________________________________________________________

___________________________________________________________________________________________________

___________________________________________________________________________________________________

Replacement parts can be obtained from your reseller or the ADC factory. When ordering replacement parts from the factory, you can FAX your order to ADC at (508) 678-9447 or telephone your order directly to the ADC Parts Department at (508) 678-9000. Please specify the dryer model number and serial number in addition to the description and part number, so that your order is processed accurately and promptly.

The illustrations on the following pages may not depict your particular dryer exactly. The illustrations are a composite of the various dryer models. Be sure to check the descriptions of the parts thoroughly before ordering.

“IMPORTANT NOTE TO PURCHASER”

Information must be obtained from your local gas supplier on the instructions to be followed if the user smells gas. These instructions must be posted in a prominent location near the dryer.

2

American Dryer Corporation

450412 - 4

Image 2
Contents ML-96 / ML-122 Model no Serial NumbersTable of Contents Cleaning Routine MaintenanceSafety Precautions Important InformationInstallation Requirements Electrical and Gas Requirements Operational Service Check ProcedureDescription of Parts Control Panel MicroprocessorSteam Coil and Damper System Gas Burner AssemblyReversing Relay Panel Steam Coil pH LevelMain Door Switch Drive Shaft AssemblyIdler Shaft Assembly Sail Switch Gas Models OnlyServicing Brushing on a soapy water solution Microprocessor Temperature Sensor Probe ReplacementGas Valve Replacement Main Burner Orifices ReplacementThermostats Burner Tubes ReplacementIgnition Module Replacement To Convert Natural Gas to L.P. GasSail Switch Assembly Gas Models Only Steam Damper Actuator System Service and ReplacementMain Door Switch Replacement Steam Coil ReplacementMay be needed to remove and install the steam coil Front Panel and Main Door AssembliesDrive Motor Pulley Replacement Front Panel ReplacementBasket Assembly Adjustment Tumbler Wheel Replacement on Drive AssemblyTumbler Wheel Replacement on Idler Assembly Rotational Sensor Assembly 15/16 5 cm Flange Bearing ReplacementInch Support Wheel Replacement Idler Shaft Pillow Block Bearing ReplacementDrive Motor V-Belts Replacement Belt Adjustment Motor to Drive AxleMotorized Impellor Blower Replacement Drive Motor ReplacementTroubleshooting Diagnostic L.E.D. Display Failure Codes Phase 6 OPL System DiagnosticsBurner hi-limit safety thermostat Is tripping Overload for impellor fan motor Is trippingD. Display Indicators D. Display Indicator NumberHT1 Heat Output L.E.D. Indicator FAN Blower Output L.E.D. IndicatorAIR AIR JET Output L.E.D. Indicator Optional Fuse Main Fuse Input L.E.D. IndicatorPhase 7 OPL System Diagnostics Diagnostic L.E.D. Display Fault MessagesInputs Input/Output Board L.E.D. IndicatorsData Label OutputsHow to Use a Manometer 450412 ADC Part No 4 01/02/08
Related manuals
Manual 59 pages 3.4 Kb

ML-96, ML-122 specifications

The ADC ML-122 and ML-96 are two advanced communication devices designed for efficient data collection and transmission in various applications. Both models are renowned for their robust performance and user-friendly features, which cater to a diverse range of industries.

The ADC ML-122 is a high-performance data logger that excels in multi-channel monitoring. It supports various input types, making it versatile for applications such as environmental monitoring, industrial process control, and research. One of its standout features is its ability to accommodate both analog and digital signals, allowing users to gather a wealth of data from different sources. The device supports a wide temperature range, ensuring reliability in diverse environmental conditions. Moreover, its built-in memory can store extensive data logs, which are easily downloadable for analysis.

On the other hand, the ADC ML-96 is designed primarily for telecommunication and network monitoring. It features advanced signal processing technologies that allow it to analyze and troubleshoot communication lines efficiently. The device is equipped with real-time monitoring capabilities, enabling users to detect issues as they arise, which is crucial in maintaining network integrity. The ML-96's compact design makes it an ideal choice for installation in tight spaces without sacrificing performance.

Both models are built with cutting-edge technologies that enhance their functionality. They integrate wireless communication protocols, such as Wi-Fi and Bluetooth, enabling seamless connectivity to cloud services for data backup and remote access. This feature empowers users to monitor conditions from anywhere, ensuring that critical information is always at hand.

The user interface for both the ML-122 and ML-96 is designed for ease of use. Equipped with a clear display and intuitive controls, users can navigate through settings and view data with minimal training. The devices also offer customizable alerts that notify users of any anomalies, adding an additional layer of security and responsiveness.

In terms of power management, both models utilize energy-efficient components, allowing for extended battery life. This is particularly advantageous in remote sensing applications where power sources may be limited. Furthermore, the ability to integrate with other systems makes these models adaptable to various operational needs.

In conclusion, the ADC ML-122 and ML-96 stand out in their respective markets due to their innovative features, reliable technologies, and user-friendly designs. With their flexibility and performance, they continue to set the standard for data logging and communication monitoring technologies.